TRACOPOWER TEP 60WIR DC/DC Converter, 48V dc/ 1.25 A, 36V dc Input, 9V Input 60 W, PCB, 90 °C Max Temp -40 °C Min Temp,

대량 구매 할인 기용 가능
View bulk pricing options

Subtotal (1 unit)*

₩187,840.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 추가로 2026년 10월 12일 부터 6 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.

수량
한팩당
1 - 4₩187,840.00
5 - 9₩185,020.00
10 - 24₩183,140.00
25 - 49₩172,780.00
50 +₩169,060.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
210-2519
Distrelec 제품 번호:
302-24-781
제조사 부품 번호:
TEN 60-2418WIR
제조업체:
TRACOPOWER
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

TRACOPOWER

Output Voltage 1

48V dc

Product Type

DC/DC Converter

Maximum Input Voltage

36V dc

Minimum Input Voltage

9V

Output Current 1

1.25A

Output Current 2

1.25A

Mount Type

PCB

Input Ratio

4:1

MTBF

724500h

Number of Outputs

1

Ripple and Noise

300mV Pk-Pk

Output Voltage Adjustment Range

10 %

Isolation Voltage

3kV

Number of Pins

8

Maximum Output Power

60W

Package Type

Encapsulated

Weight

66.9g

Width

40.7mm

Depth

25.4mm

Standards/Approvals

No

Length

50.8mm

Series

TEP 60WIR

Minimum Operating Temperature

-40°C

Efficiency

92%

Maximum Operating Temperature

90°C

제외

COO (Country of Origin):
TW

TRACOPOWER TEP 60WIR Series DC-DC Converter, 0.92 Efficiency, 3kV Isolation Voltage - TEN 60-2418WIR


This DC-DC converter efficiently transforms an input voltage range of 9 to 36V DC into a stable output of 48V DC. It is suitable for applications that require dependable power supply solutions, particularly in the railway sector due to its robust design and adherence to strict electrical standards.

Features & Benefits


• Supports a wide input voltage range for various applications

• High efficiency minimises power loss during conversion

• Isolated design enhances safety in sensitive environments

• Adjustable output voltage meets different load requirements

• Compact design facilitates easy integration into limited spaces

• Railway approved, ensuring compliance with industry regulations

Applications


• Power conditioning in railway infrastructure

• Control systems in railway operations

• Automation processes in transportation vehicles

What is the maximum temperature limit for operation?


The converter can operate effectively up to +85°C for consistent performance.

How does the output voltage adjustment work?


The output voltage can be adjusted from -10% to +10% using an external trim resistor.

Is this suitable for outdoor use?


It is designed primarily for enclosed applications; outdoor suitability depends on housing.

What happens if I exceed the voltage input limit?


Exceeding the input voltage can damage the converter, leading to failure.

Can this be used in medical applications?


No, it is not approved for medical applications, only for railway use.

관련된 링크들