Circuit Trips | Auto Reclosers | RS
최근 검색 기록

    Circuit Trips

    Circuit trips react to ground faults, short circuits or thermal overload in circuit breakers. A circuit trip opens the circuit in the event of a faulty condition. The trip becomes activated when it senses heat from an overload or high current from a short circuit.

    What are the different types of circuit trips?

    There are two types of circuit trips: electromechanical and electronic. An electromechanical circuit trip has two moving parts that work together to determine when to open the circuit. The two parts are a current-sensitive device and a thermal-sensitive device. An electric circuit trip is less mechanical as it's a programmable device. It measures and times the current flowing through the circuit breaker, electronically delivering a trip signal when it's needed.

    How to choose the right circuit trips

    Choosing the right circuit trips depends on the circuit or device and appliance you're using it for. There are various features that should be considered when selecting the right circuit trips, such as rated-control voltage and the current rating.

    An auto recloser is a type of circuit breaker equipped with a mechanism that automatically closes the breaker after it has been opened due to a fault. Reclosers are used to detect overcurrent and interrupt momentary faults in electrical distribution networks. To prevent damage, each station along a network is protected with circuit breakers which turn the power off if there is a short circuit. Reclosers are programmed to automate the reset process and start the restoration service.

    Why Have an Auto Recloser?

    Firstly, reclosers prevent transient short circuits from triggering prolonged power outages. This could be a broken tree branch momentarily hitting an overhead cable before it hits the ground. Having a recloser results in a better service to the customer as the power is restored within a few seconds.

    Secondly, the recloser is able to restore power automatically without the requirement of an engineer unless the fault is more serious.

    318 표시되는 제품 Circuit Trips

    Eaton
    -
    Xboard
    -
    N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4) Series, NZM3(-4) Series
    Shunt Trip
    208 → 250V ac/dc
    -
    -
    Schneider Electric
    -
    Multi 9
    M9A
    Multi 9 C60 C60BP, Multi 9 C60 C60BPR, Multi 9 C60 C60SP, Multi 9 C60H-DC, Multi 9 GFP
    -
    -
    Yes
    Green Premium
    Schneider Electric
    100A
    Acti 9
    SEA9TB
    Acti 9 Isobar A Type Distribution Boards, Acti9 Isobar B Type Distribution Boards
    -
    -
    Yes
    Green Premium
    Eaton
    -
    -
    -
    FAZ Series MCB/RCBO
    Undervoltage Release
    230V ac
    -
    -
    Siemens
    25A
    -
    Sentron
    -
    Remote Switch
    230V ac
    -
    -
    Schneider Electric
    40A
    Compact
    TM-G
    Compact NSX 100/160 Circuit Breakers
    -
    690 V ac, 750V dc
    Yes
    Green Premium
    ABB
    16A
    E200
    E201
    Commanding Loads
    Isolator
    230V ac
    -
    -
    Siemens
    25A
    -
    Sentron
    -
    -
    24V ac
    -
    -
    Siemens
    63A
    Sentron
    -
    -
    -
    -
    -
    -
    Schneider Electric
    -
    Acti 9
    MNs
    C120 Series, C60 Series, ID Residual Current Device, IDPN Residual Current Device
    Undervoltage Release
    220 → 240V ac
    Yes
    Green Premium
    Siemens
    63A
    -
    Sentron
    -
    -
    230V ac
    -
    -
    Eaton
    -
    Xboard
    -
    N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4) Series, NZM3(-4) Series
    Undervoltage Release
    208 → 240V ac
    -
    -
    Eaton
    -
    Eaton Moeller
    IZMX/INX
    IZMX…
    Circuit Trip
    -
    -
    -
    Schneider Electric
    20A
    Acti 9
    iPB
    -
    Push Button
    250V ac
    Yes
    Green Premium
    ABB
    -
    E200
    E202
    Commanding Load
    Isolator
    -
    -
    -
    Schneider Electric
    -
    Acti 9
    iMNs
    ARA, ic60 MCB, IDPN Vigi, ild Double Terminal, ilD MCB, iSW-NA, RCA
    Undervoltage Release
    220 → 240V ac
    Yes
    Green Premium
    Schneider Electric
    40A
    Compact
    TM-D
    Compact NSX 100/160 Circuit Breakers
    -
    690V ac
    Yes
    Green Premium
    Eaton
    -
    Xboard
    -
    N(S)1(-4) Series, NZM1(-4) Series
    Shunt Trip
    24V ac/dc
    -
    -
    Legrand
    63A
    -
    -
    RCBO, RCCB
    Auto Recloser
    230V (Volts)
    -
    -
    Siemens
    25A
    -
    Sentron
    -
    -
    230V ac
    -
    -
    페이지 당 결과 수