Festo Vacuum Pump, 1.4 mm nozzle, 5 bar 92.6 L/min, VN series

Subtotal (1 unit)*

₩335,380.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 3 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩335,380.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
203-6292
제조사 부품 번호:
VN-14-L-T4-PQ3-VQ3-RO2-M
제조업체:
Festo
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Festo

Product Type

Vacuum Pump

Maximum Suction Flow

92.6L/min

Maximum Vacuum Pressure

5bar

Nozzle Diameter

1.4mm

Series

VN

Silencer

Yes

Inlet Thread Standard

QS

Maximum Operating Temperature

50°C

Hazardous Area Certification

No

Standards/Approvals

ISO8573-1:2010 (7:4:4), Conforms to RoHS

COO (Country of Origin):
HU

Festo Series VN Vacuum Pump, 92.6L/min Maximum Suction Flow, 5 Bar Maximum Vacuum Pressure - VN-14-L-T4-PQ3-VQ3-RO2-M, Numeric Part Number: 532645


This vacuum pump is a Compact device designed to generate suction for industrial automation and handling tasks. It is suited to integration where confined space and noise reduction matter, providing controllable vacuum performance for grippers and pick-and-place systems in electrical, electronics and mechanical production environments.

Features and Benefits:


• Maximum suction flow of 92.6 L/min delivers Rapid part pick-up
• Maximum vacuum pressure of 5 bar enables secure holding force
• 1.4mm nozzle reduces footprint while maintaining throughput
• QS inlet simplifies connection and maintenance procedures
• Operates up to 50 °C for use in warm production zones
• Integrated silencer lowers acoustic emissions during operation

Applications


• Suitable for gripper systems in automated assembly lines
• Ideal for pick-and-place of electronic components
• Used with vacuum cups for small-part handling in electronics
• Can be used for board handling in PCB assembly stations

What approvals or standards relate to Air quality for this unit?


It conforms to ISO 8573-1:2010 particulate and humidity classes 7:4:4 specifying compressed Air quality parameters for contamination and moisture levels.

Is the unit restricted for use in hazardous atmospheres?


No hazardous area certification is provided, so it should not be used where specific explosion-protection certification is required.

How does environmental regulation affect selection?


The product is RoHS compliant, indicating materials meet restrictions on certain hazardous substances for electronic and electrical applications.

What connection type should be prepared on the supply side?


A QS‑standard inlet fitting is required for correct pneumatic connection and straightforward replacement.