Omron H5CC Series Flush Timer Relay, 1-Contact, 12 to 48 V dc 12V ac, 48 V ac, 0.001 s to 999999h h, 2-Function
- RS 제품 번호:
- 402-689
- 제조사 부품 번호:
- H5CC-ASD
- 제조업체:
- Omron
Subtotal (1 unit)*
₩436,000.50
일시적 품절
- 2026년 7월 23일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩436,000.50 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 402-689
- 제조사 부품 번호:
- H5CC-ASD
- 제조업체:
- Omron
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Omron | |
| Product Type | Timer Relay | |
| Function | Timer | |
| Mount Type | Flush | |
| Time Range | 0.001 s to 999999h h | |
| Number of Contacts | 1 | |
| Switching Voltage | 250V ac | |
| Number of Timer Functions | 2 | |
| IP Rating | IP66 | |
| Supply AC Voltage | 12, 48V ac | |
| Timing Adjustment | Polar | |
| Minimum Operating Temperature | -10°C | |
| Contact Current | 5A | |
| Supply DC Voltage | 12 to 48 V dc | |
| Maximum Operating Temperature | 55°C | |
| Standards/Approvals | UL508, CCC, RCM, EN61812-1, CSA C22.2 No. 14, VDE0106/P100, cULus, UKCA, cURus | |
| Width | 48mm | |
| Height | 48mm | |
| Length | 59mm | |
| Series | H5CC | |
| 모두 선택 | ||
|---|---|---|
브랜드 Omron | ||
Product Type Timer Relay | ||
Function Timer | ||
Mount Type Flush | ||
Time Range 0.001 s to 999999h h | ||
Number of Contacts 1 | ||
Switching Voltage 250V ac | ||
Number of Timer Functions 2 | ||
IP Rating IP66 | ||
Supply AC Voltage 12, 48V ac | ||
Timing Adjustment Polar | ||
Minimum Operating Temperature -10°C | ||
Contact Current 5A | ||
Supply DC Voltage 12 to 48 V dc | ||
Maximum Operating Temperature 55°C | ||
Standards/Approvals UL508, CCC, RCM, EN61812-1, CSA C22.2 No. 14, VDE0106/P100, cULus, UKCA, cURus | ||
Width 48mm | ||
Height 48mm | ||
Length 59mm | ||
Series H5CC | ||
- COO (Country of Origin):
- CN
Omron H5CC Series Timer Relay, 0.001s to 999999h Time Range, 5A Contact Current - H5CC-ASD
This timer relay provides adjustable time control for automation and control systems, offering multiple timing functions within a Compact panel-mounted unit. It operates across AC and DC supplies and is intended for installations requiring a single switched output and environmental protection in challenging conditions.
Features and Benefits:
• SPST contact rated at 5A for straightforward switching applications
• Time range 0.001s-999999h for extremely fine to very long delays
• AC/DC supply 12V or 48V compatibility for flexible system integration
• IP66 ingress protection allowing use in dusty and water-exposed environments
• Polar timing adjustment enabling precise selection of delay settings
• Screw Terminal connections for secure wiring and serviceability
• Time range 0.001s-999999h for extremely fine to very long delays
• AC/DC supply 12V or 48V compatibility for flexible system integration
• IP66 ingress protection allowing use in dusty and water-exposed environments
• Polar timing adjustment enabling precise selection of delay settings
• Screw Terminal connections for secure wiring and serviceability
Applications
• Suitable for machinery control where single-circuit timing is required
• Ideal for delayed start sequences in electrical panels
• Used for interval timing in process automation systems
• Can be used for pump control where waterproof protection is needed
• Suitable for maintenance-by-replacement in Compact control assemblies
• Ideal for delayed start sequences in electrical panels
• Used for interval timing in process automation systems
• Can be used for pump control where waterproof protection is needed
• Suitable for maintenance-by-replacement in Compact control assemblies
What contact arrangement does it provide and how does that affect circuit design?
It uses a single-pole single-throw contact, so it switches one circuit path and is best applied where a single make/break output suffices.
Which voltage options are available for supply and how do they influence wiring?
The unit accepts discrete AC supplies at 12V or 48V and DC supplies from 12V to 48V, permitting connection to common control supplies while requiring correct selection to match system voltage.
What environmental limits should installers observe for reliable operation?
The relay is rated for operation between -10°C and 55°C and carries an IP66 enclosure rating, so it must be mounted where ambient temperatures remain within that band and where protection from dust and powerful water jets is required.
How is the relay mounted and connected in panel assemblies?
It is designed for flush mounting and terminates via screw-type terminals, enabling integration into panel cut-outs with conventional fastening and wire termination methods.
관련된 링크들
- Omron H5CC Series Flush Timer Relay, 1-Contact, 12 to 48 V dc 12V ac, 48 V ac, 0.001 s to 999999h h, 2-Function
- Omron H5CC Series Flush Timer Relay, 1-Contact, 12 to 48 V dc 12V ac, 48 V ac, 0.001 s to 999999h h, 2-Function, SPDT
- Omron H5CC Series Flush Timer Relay, 1-Contact, 12 to 48 V dc 24V, 0.001 s to 999999h h, 2-Function, SPDT Switch
- Omron H5CC Series Flush Timer Relay, 1-Contact, 100 to 240 V 100V ac, 240 V ac, 0.001 s to 999999h h, 2-Function, SPDT
- Omron H5CC Series Flush Timer Relay, 1-Contact, 100 to 240 V dc 100V ac, 240 V ac, 0.001 s to 999999h h, 2-Function,
- Omron H5CC Series Flush Timer Relay, 1-Contact, 100 to 240 V dc 100V ac, 240 V ac, 0.001 s to 999999h h, 2-Function
- Omron H5CC Series Flush Timer Relay, 1-Contact, 24 to 240 V dc 24V ac, 240 V ac, 0.001 s to 999999h h, 2-Function, SPDT
- Omron H5CC Series Flush Timer Relay, 1-Contact, 100 to 240 V dc 100V ac, 240 V ac, 0.001 s to 999999h h, 2-Function, 2 x