Omron H5CC Series Flush Timer Relay, 1-Contact, 12 to 48 V dc 12V ac, 48 V ac, 0.001 s to 999999h h, 2-Function
- RS 제품 번호:
- 402-691
- 제조사 부품 번호:
- H5CC-AUD
- 제조업체:
- Omron
Subtotal (1 unit)*
₩436,000.50
일시적 품절
- 2026년 7월 22일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩436,000.50 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 402-691
- 제조사 부품 번호:
- H5CC-AUD
- 제조업체:
- Omron
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Omron | |
| Product Type | Timer Relay | |
| Mount Type | Flush | |
| Function | Multifunction | |
| Time Range | 0.001 s to 999999h h | |
| Number of Contacts | 1 | |
| Switching Voltage | 250V ac | |
| Number of Timer Functions | 2 | |
| IP Rating | IP66 | |
| Timing Adjustment | Polar | |
| Supply DC Voltage | 12 to 48 V dc | |
| Contact Current | 5A | |
| Minimum Operating Temperature | -10°C | |
| Supply AC Voltage | 12, 48V ac | |
| Maximum Operating Temperature | 55°C | |
| Length | 59mm | |
| Width | 48mm | |
| Height | 48mm | |
| Standards/Approvals | UKCA, CCC GB/T 14048.5, EN61812-1, VDE0106/P100, cULus (or cURus) UL508/CSA C22.2 No. 14, RCM | |
| Series | H5CC | |
| 모두 선택 | ||
|---|---|---|
브랜드 Omron | ||
Product Type Timer Relay | ||
Mount Type Flush | ||
Function Multifunction | ||
Time Range 0.001 s to 999999h h | ||
Number of Contacts 1 | ||
Switching Voltage 250V ac | ||
Number of Timer Functions 2 | ||
IP Rating IP66 | ||
Timing Adjustment Polar | ||
Supply DC Voltage 12 to 48 V dc | ||
Contact Current 5A | ||
Minimum Operating Temperature -10°C | ||
Supply AC Voltage 12, 48V ac | ||
Maximum Operating Temperature 55°C | ||
Length 59mm | ||
Width 48mm | ||
Height 48mm | ||
Standards/Approvals UKCA, CCC GB/T 14048.5, EN61812-1, VDE0106/P100, cULus (or cURus) UL508/CSA C22.2 No. 14, RCM | ||
Series H5CC | ||
- COO (Country of Origin):
- CN
Omron H5CC Series Timer Relay, 0.001s to 999999h Time Range, 5A Contact Current - H5CC-AUD
This timer relay provides configurable timing functions for control systems in industrial environments, offering selectable contact arrangements and multiple supply-voltage options to handle varied automation tasks. It is designed for flush mounting and suits applications where a robust timing device with a wide operating temperature range is required.
Features and Benefits:
• Single-contact output supports straightforward switching up to 5 A
• Multifunction timing covers two selectable timer behaviours
• Wide supply range accepts 12-48V DC and 12V/48V AC inputs
• Time setting spans 0.001 s to 999,999 h for fine control
• Screw terminals enable secure field-wiring connections
• Polar adjustment allows precise tuning of timing intervals
• Multifunction timing covers two selectable timer behaviours
• Wide supply range accepts 12-48V DC and 12V/48V AC inputs
• Time setting spans 0.001 s to 999,999 h for fine control
• Screw terminals enable secure field-wiring connections
• Polar adjustment allows precise tuning of timing intervals
Applications
• Suitable for sequenced machinery start-stop control in factories
• Ideal for delay functions in conveyor and material-handling systems
• Used for automated lighting and signalling timing on industrial sites
• Can be used for process-control timing in electrical panels
• Used with motor-control circuits requiring SPDT or SPST switching
• Ideal for delay functions in conveyor and material-handling systems
• Used for automated lighting and signalling timing on industrial sites
• Can be used for process-control timing in electrical panels
• Used with motor-control circuits requiring SPDT or SPST switching
What contact arrangements are available and how do they affect use?
You can choose between SPDT and SPST contact formats to match control logic
SPDT permits changeover switching while SPST provides single-circuit make-or-break control.
How does the unit cope with harsh or wet environments?
The enclosure is rated to IP66, allowing protection against dust ingress and powerful water jets, making it suitable for washdown or exposed locations.
What Terminal and mounting provisions ease installation?
Connections are MADE via screw terminals for robust conductor retention, and the device is intended for flush-panel mounting to save panel depth.
What electrical limits should installers observe for safe operation?
The relay switches up to 250 VAC and carries contact currents up to 5 A
observe these limits when specifying loads and protective devices.
관련된 링크들
- Omron H5CC Series Flush Timer Relay, 1-Contact, 12 to 48 V dc 12V ac, 48 V ac, 0.001 s to 999999h h, 2-Function
- Omron H5CC Series Flush Timer Relay, 1-Contact, 12 to 48 V dc 12V ac, 48 V ac, 0.001 s to 999999h h, 2-Function, SPDT
- Omron H5CC Series Flush Timer Relay, 1-Contact, 12 to 48 V dc 24V, 0.001 s to 999999h h, 2-Function, SPDT Switch
- Omron H5CC Series Flush Timer Relay, 1-Contact, 100 to 240 V 100V ac, 240 V ac, 0.001 s to 999999h h, 2-Function, SPDT
- Omron H5CC Series Flush Timer Relay, 1-Contact, 100 to 240 V dc 100V ac, 240 V ac, 0.001 s to 999999h h, 2-Function,
- Omron H5CC Series Flush Timer Relay, 1-Contact, 100 to 240 V dc 100V ac, 240 V ac, 0.001 s to 999999h h, 2-Function
- Omron H5CC Series Flush Timer Relay, 1-Contact, 24 to 240 V dc 24V ac, 240 V ac, 0.001 s to 999999h h, 2-Function, SPDT
- Omron H5CC Series Flush Timer Relay, 1-Contact, 100 to 240 V dc 100V ac, 240 V ac, 0.001 s to 999999h h, 2-Function, 2 x