Gossen Metrawatt METRACABLE TDR PRO Time Domain Reflectometer, Bluetooth Interface 12.25 ns 2500 ns

대량 구매 할인 받기

5개 더 담고 4% 할인 받기

View bulk pricing options

Subtotal (1 unit)*

₩2,901,780.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 1 개 단위 배송 준비 완료
  • 추가로 다른 지역에서 9 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.

수량
한팩당
절감
1 - 4₩2,901,780.00-
5 +₩2,756,700.004%

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
226-1537
Distrelec 제품 번호:
302-17-272
제조사 부품 번호:
M281A
제조업체:
Gossen Metrawatt
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Gossen Metrawatt

Accuracy

1 %

Product Type

Time Domain Reflectometer

Resolution

300 mm

Maximum Pulse Width

2500 ns

Minimum Pulse Width

12.25ns

Pulse Amplitude

20V pp

Interface Type

Bluetooth

Battery Life

30h

Minimum Operating Temperature

-10°C

Battery Type

Nickel-Metal Hydride, LR06, AA

Maximum Operating Temperature

50°C

Display Type

LCD

Standards/Approvals

EN 55011: 2015, EN 6100042: 2009

Weight

390g

Power Source

1.2 V Battery, 1.5 V Battery

Model Number

METRACABLE TDR PRO

COO (Country of Origin):
DE

Gossen-Metrawatt Time Domain Reflectometer, 20V Pulse Amplitude, 1% Accuracy - M281A


This time domain reflectometer is a handheld instrument designed to locate faults and measure cable length in wiring networks. It operates across a wide temperature range and presents results on an integrated LCD, while pairing wirelessly via Bluetooth for remote monitoring. The unit accepts common rechargeable and primary AA battery types and is intended for field use by technicians requiring portable diagnostics.

Features and Benefits:


• *Made in Germany
• 300 mm resolution delivers fine-grained distance detection
• 1% accuracy reduces uncertainty in length measurements
• 20 V p-p Pulse improves fault return visibility
• 12.25 ns to 2500 ns Pulse width supports variable cable types
• 30 h battery life enables extended field operation

Applications


• Suitable for locating impedance discontinuities in coaxial runs
• Ideal for pinpointing breaks in long cable segments
• Used for verifying repaired joints and terminations
• Can be used for commissioning new network cabling
• Suitable for on-site diagnostics in varying ambient conditions

What battery chemistries can I use in the device?


It accepts nickel to metal hydride cells and LR06 AA primary cells depending on availability.

How is the instrument interfaced for data review?


It uses Bluetooth connectivity alongside the built-in LCD for local or remote observation.

What environmental limits govern field use?


The operating temperature range spans -10 °C to 50 °C for typical outdoor and indoor conditions.

What standards relate to electromagnetic behaviour and immunity?


The unit conforms to EN 55011:2015 for emissions and EN 61000-4-2:2009 for electrostatic discharge immunity.