Siemens Stainless Steel Temperature Sensor, -25 °C Min, 95 °C Max

Subtotal (1 unit)*

₩44,940.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 26 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩44,940.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
287-8733
제조사 부품 번호:
QAP1030.200 / BPZ:QAP1030.200
제조업체:
Siemens
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Siemens

Product Type

Temperature Sensor

Minimum Temperature Sensed

-25°C

Maximum Temperature Sensed

95°C

Probe Length

2m

Cable Length

2m

Accuracy

±1.4 K

Material

Stainless Steel

COO (Country of Origin):
RO

Siemens Temperature Sensor, 95°C Maximum Temperature, 2m Probe Length - QAP1030.200 / BPZ:QAP1030.200


This temperature sensor monitors surface temperature and converts thermal changes into a resistance-based signal for HVAC control systems. It is intended for strap-on or surface mounting where immersion sensing is impractical, providing a practical method to infer fluid or duct conditions via pipe or duct surfaces. The unit incorporates a stainless-steel probe and a cable for remote connection to building automation or control equipment.

Features & Benefits


• Stainless-steel probe provides Durable contact and corrosion resistance
• Measurement range covers -25°C to 95°C enabling hot and chilled fluid monitoring
• ±1.4 K accuracy ensures consistent readings for control loops
• Outputs as thermistor/RTD or current allow compatibility with control inputs
• Rapid response to temperature change supports timely control actions

**Applications**


• Suitable for surface temperature monitoring on pipework in plant rooms
• Ideal for duct air-temperature checks during commissioning and maintenance
• Used with building controls to infer fluid temperature where immersion is not feasible
• Can be fitted inside a protection tube for slab temperature acquisition
• Suitable as a changeover sensor with room thermostats when configured accordingly

What sensing element types are available for this family of sensors?


The product family supports various outputs including 100 kΩ thermistor, 10 kΩ Type II thermistor, 1 kΩ Ni RTD and Pt RTD options, and 4 to 20 mA.

How does the sensor connect to HVAC control hardware?


The sensor uses a 2m cable to deliver a resistance or current signal compatible with common HVAC controllers and thermostats.

Can it be used where immersion sensors cannot be installed?


Yes

it is specifically intended for strap-on or surface mounting to provide a surrogate measurement when full immersion installation is impractical.

How is it deployed for concrete slab measurements?


When used with a suitable protection tube the strap-on cable probe can be positioned to acquire slab temperatures without direct exposure.

What practical benefit does the stainless-steel probe offer in industrial settings?


The probe material gives mechanical robustness and improved resistance to environmental wear where probe contact with pipe surfaces is required.