Entrelec, M 4/9 PV Surge Suppressor Unit 130V dc Maximum Voltage Rating 2.5 kA Maximum Surge Current Terminal Block with
- RS 제품 번호:
- 413-2397
- 제조사 부품 번호:
- 1SNA007013R1300
- 제조업체:
- Entrelec
본 이미지는 참조용이오니 재확인이 필요하시면 문의해주세요.
Subtotal (1 unit)*
₩42,200.00
일시적 품절
- 2027년 2월 08일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩42,200.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 413-2397
- 제조사 부품 번호:
- 1SNA007013R1300
- 제조업체:
- Entrelec
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Entrelec | |
| Product Type | Surge Suppressor Unit | |
| Suppressor Type | Terminal Block with Transient Voltage Suppressor | |
| Maximum Voltage | 130V dc | |
| Mount Type | DIN Rail | |
| Maximum Surge Current | 2.5kA | |
| Series | M 4/9 PV | |
| Minimum Operating Temperature | -55°C | |
| Maximum Operating Temperature | 130°C | |
| Depth | 64.5mm | |
| Length | 65.5mm | |
| Standards/Approvals | ANSI/ESD S20.20:2014 | |
| Height | 100mm | |
| Hazardous Area Certification | No | |
| 모두 선택 | ||
|---|---|---|
브랜드 Entrelec | ||
Product Type Surge Suppressor Unit | ||
Suppressor Type Terminal Block with Transient Voltage Suppressor | ||
Maximum Voltage 130V dc | ||
Mount Type DIN Rail | ||
Maximum Surge Current 2.5kA | ||
Series M 4/9 PV | ||
Minimum Operating Temperature -55°C | ||
Maximum Operating Temperature 130°C | ||
Depth 64.5mm | ||
Length 65.5mm | ||
Standards/Approvals ANSI/ESD S20.20:2014 | ||
Height 100mm | ||
Hazardous Area Certification No | ||
제외
Surge Protected Terminal Block
Grey nylon polyamide 6.6 moulding
Captive terminal screws with hardened heads
Compact 9mm spacing size
Deep Top Hat or G type rail mounting
Location category Zone 2
Dimensions 65.5 x 67mm
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
관련된 링크들
- Murrelektronik Limited, Limited Surge Suppressor Surge Suppressor Unit 575V ac Maximum Voltage Rating Surge Suppressor
- Murrelektronik Limited, Limited Surge Suppressor Surge Suppressor Unit 400V ac Maximum Voltage Rating Surge Suppressor
- WAGO, 792 Surge Suppressor Unit 24V dc Maximum Voltage Rating 300 A Maximum Surge Current Surge Suppressor
- WAGO, 792 Surge Suppressor Unit 24V dc Maximum Voltage Rating 10 A Maximum Surge Current Surge Suppressor
- Murrelektronik Limited, 23011 Surge Suppressor Unit 400V Maximum Voltage Rating Surge Suppressor
- Murrelektronik Limited, 23115 Surge Suppressor Unit 400V Maximum Voltage Rating Surge Suppressor
- Murrelektronik Limited, 236082 Surge Suppressor Unit 575V Maximum Voltage Rating Surge Suppressor
- Murrelektronik Limited, Limited Surge Suppressor Surge Suppressor Unit 30V Maximum Voltage Rating