Phoenix Contact DEK-OE- 24DC/24DC/100KHZ Series Solid State Relay, DIN Rail Mount

Subtotal (1 unit)*

₩77,061.20

Add to Basket
수량 선택 또는 입력
재고있음
  • 59 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩77,061.20

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
533-0019
제조사 부품 번호:
2964283
제조업체:
Phoenix Contact
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Phoenix Contact

Mounting Type

DIN Rail

Switching Type

1NO Contact

Terminal Type

Screw

Contact Configuration

SPST

Relay Type

Solid State Relay

Series

DEK-OE- 24DC/24DC/100KHZ

Dimensions

6.2 x 56 x 80mm

Height

80mm

Depth

56mm

Special Features

Reverse Polarity Protection, Surge Protection

Length

6.2mm

Operating Temperature Range

-20 → +60°C

Maximum Operating Temperature

+60°C

Minimum Operating Temperature

-20°C

COO (Country of Origin):
CN

Phoenix Contact Solid State Relay, Overvoltage Category II Rating, 100kHz Transmission Frequency - DEK-OE- 24DC/ 24DC/100KHZ - 2964283


Controlling your circuits is a breeze with this solid state relay from Phoenix Contact. When supplied with 24V DC, it makes or breaks a connected circuit of 4 to 30V DC in a jiffy. The unit contains no moving parts, which eliminates the risk of wear and tear to ensure a long service life. A 2.5kV AC test voltage rating means it also holds its own against sudden electrical surges.
This versatile terminal block accepts wires in a broad cross-section range between 0.2 and 2.5mm², including rigid and flexible conductors. Measuring just 6.2 (W) x 80 (H) x 56mm (D), it's a compact choice that fits into tight mounting areas. SSMs like this have many uses – you'll find them everywhere from medical equipment and multiplexers to I/O subsystems.

Features & Benefits


• Low current rating of 6mA means it saves energy
• Built-in LED indicator so you can easily monitor operating voltage
• Mountable on a DIN rail in any position for added flexibility
• IEC 60947-5-1 compliance shows it meets the design requirements for control-circuit devices and switching elements internationally
• Performs in temperatures between -20°C and +60°C, so it's suitable for use in challenging environments

Note

Use of EB 80-DIK... bridges in the DEK terminal blocks: Absorption of humidity from the ambient air as well as an unfavourable tolerance between a larger number of DEK terminal blocks and the EB 80-DIK... bridge may cause (minor) expansion of the DEK housing. When the EB 80-DIK... bridges are used, therefore, it is recommended that these be disconnected after about 10 to 12 DEK terminal blocks and a wire bridge to the next DEK terminal block be inserted in their place.