Schneider Electric XPS CM, 24V dc Safety Relay, 2 Safety Contacts, 4

현재 비가용
RS는 이 제품을 더 이상 판매하지 않습니다.

대체품

이 제품은 현재 공급 불가입니다. 아래 제품들은 당사에서 추천드리는 대체품입니다.

RS 제품 번호:
477-8684
제조사 부품 번호:
XPSCM1144
제조업체:
Schneider Electric
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Schneider Electric

Product Type

Safety Relay

Safety Contacts

2

Number of Auxiliary Contacts

4

Reset Method

Power Button

Mount Type

DIN Rail

Series

XPS CM

Power Consumption

15W

Terminal Type

Screw

IP Rating

IP20, IP40

Minimum Operating Temperature

-10°C

Standards/Approvals

EN 1088, CEI 61496-2, DIN 31001-1, EN 60 204-1, prEN 999, EN 614-1, EN 294, EN 292-1, CEI 61496-1, EN 1050, EN 811, EN 292-2, EN 954-1, EN 953, EN 349

Maximum Operating Temperature

55°C

Length

99mm

Width

45mm

Height

114mm

Hazardous Area Certification

No

Safety Category

CAT 2

Coil Voltage

24V dc

제외

Schneider Electric XPS CM Series Safety Relay, 99mm Length, 4 Contacts - XPSCM1144


This safety relay is intended to improve safety in industrial applications by monitoring single beam photoelectric sensors. It is crucial for scenarios where safety and reliability are essential, helping to prevent accidents and maintain compliance with safety regulations. The device features advanced capabilities that enable users to create strong safety systems in accordance with various standards, including ISO 13849-1.

Features & Benefits


• Meets ISO 13849-1 Category 2 for improved safety

• Includes built-in muting for enhanced operational efficiency

• MTTFd of 16.6 years, ensuring long-term dependability

• Supports 4 auxiliary contacts for flexible connections

• High safety integrity with a DC of 95.5%

• Rated insulation voltage of 300V for increased protection

Applications


• Monitoring safety light curtains in automation systems

• Suitable for requiring light beam safety detection

• Applicable in environments needing compliance with SIL 1 standards

• Used in industrial settings for critical safety functions

What type of sensors are compatible with this device?


This safety relay is compatible with various sensors, including infrared sensors for safe monitoring and muting operations.

What power supply is required for operation?


It requires a 24V DC power supply, ensuring compatibility with standard industrial electrical systems.

How can I ensure proper installation?


Correct wiring must be followed as per the outlined specifications, ensuring that all connections meet safety standards.

What is the maximum allowable duration for muting operations?


The muting function can last up to 60 seconds, providing flexibility during operation while maintaining safety.

How does this device signal operational status?


It is equipped with multiple LEDs indicating fuse status, restart functions, and the state of safety outputs to inform users of its operational status.

관련된 링크들