Pilz PNOZ X3, 24V ac/dc Safety Relay, 3 Safety Contacts, 1

Subtotal (1 unit)*

₩510,940.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 추가로 2026년 11월 30일 부터 162 개 단위 배송
  • 추가로 2026년 12월 07일 부터 33 개 단위 배송
  • 추가로 2027년 1월 18일 부터 54 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩510,940.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
245-1848
Distrelec 제품 번호:
300-77-769
제조사 부품 번호:
774310
제조업체:
Pilz
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Pilz

Product Type

Safety Relay

Safety Contacts

3

Contact Configuration

3 NO/1 NC

Number of Auxiliary Contacts

1

Mount Type

DIN Rail

Series

PNOZ X3

Power Consumption

2.5W

Terminal Type

Screw

IP Rating

IP20, IP40, IP54

Contact Current

8A

Standards/Approvals

EN 60068-2-6, EN 60947-5-1, EN ISO 13849-1:2006, EN 954-1, IEC 61511, EN 60947-4-1, EN 61000-6-2, EN 60947-1, EN 60068-2-78, EN IEC 62061, VDE 0113-1, EN 60204-1

Switching AC Voltage

240V ac

Switching DC Voltage

24V dc

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

55°C

Width

45mm

Length

87mm

Height

121mm

Hazardous Area Certification

No

Safety Category

CAT 4

Coil Voltage

24V ac/dc

PNOZ X3 Series of Safety Relays by PILZ


The PNOZ X3 range of Safety Relays by PILZ introduces your circuit to a safety related interruption wherein the primary applications are typically in potential hazardous environments where you need that quick power cut off. Particularly useful in automated environments with high foot traffic such as factories and warehouses.

Features and benefits


• LED indicator statuses to support switching channel status between 1 or 2 signals & also for monitoring the supply voltage currently in the relay;• Semiconductor output signals: switch status channel 1 / 2 ;• 3 safety contacts and 1 auxiliary contact;• Several connection outputs & status indicators;• Your opening and closing of the safety function relays is tested automatically within each on-off cycle;• A monitored manual reset is available in this unit;• DIN rail mounting as standard

Safety features


• The circuit is redundant with built in self-monitoring ;• Reliable X3 functionality means your safety function remains effective even in the event of component failure;• The transformer is short circuit proof and an electronic fuse is used on a DC supply.

Applications

• Emergency stop buttons
• Safety gates


Technical safety parameters

• EN 60204-1;• EN 60947-5-1;• VDE 0113-1

Approvals

CE, cULus Listed, TÜV, KOSHA, CCC.