SICK I15 Safety Switch, Power, Fibreglass Reinforced Thermoplastic

Subtotal (1 unit)*

₩547,160.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 12월 17일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩547,160.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-1833
제조사 부품 번호:
i15-EP0133 Lock
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Lock Style

Power

Product Type

Safety Switch

Actuator Included

No

Safety Contacts

1 NC

Housing Material

Fibreglass Reinforced Thermoplastic

Series

I15

IP Rating

IP67

Switch Contact Current

1mA

Contact AC Voltage

230V ac

Contact DC Voltage

24V dc

Minimum Operating Temperature

-20°C

Hazardous Area Certification

No

Maximum Operating Temperature

55°C

Standards/Approvals

CE

Length

96mm

Width

42mm

Number of Head Directions

4

Depth

37.5mm

COO (Country of Origin):
DE

SICK I15 Series Safety Switch, IP67, Fibreglass Reinforced Thermoplastic Housing - i15-EP0133 Lock


This safety switch is an electro-mechanical interlock designed to secure access to machinery and hazardous zones. It uses a power-to-lock mechanism and is intended for industrial installations where a compact, sealed switching device is required. The unit operates within a defined ambient range and connects via a single M20 cable gland, with the actuator supplied separately.

Features and Benefits:


• Power-to-lock mechanism provides secure retention up to 1000N
• 1 NC safety contact enables monitoring with low current loads
• Solenoid supply operates at 20.4 VDC-26.4 VDC for controlled locking
• IP67 enclosure protects against dust ingress and temporary immersion
• Suitable for frequent actuation up to 7000 cycles per hour

Applications


• Suitable for safeguarding access to production machinery
• Used with guarded doors requiring monitored locking
• Ideal for systems requiring Compact safety interlocks
• Can be used in wet or dusty industrial environments

What type of electrical outputs does it provide?


It provides electro-mechanical contacts with slow-action switching elements and supports AC-15/DC-13 usage categories.

How should the unit be wired into a safety circuit?


Individual wiring with diagnostics is required

fault detection is handled by the connected safety logic unit.

What are the environmental operating limits for the device?


It functions between -20°C and +55°C and can be stored within the same temperature range.

Is an actuator included with delivery?


No, the actuator is not supplied and must be ordered separately.

What mechanical forces are relevant to installation?


The device requires an actuation force of at least 35N and resists forces of up to 30N

locking forces of 1000N and 700N apply to specific standards.