Omron D4GS Safety Rated Interlock Switch, Keyed, Plastic, Key

Subtotal (1 unit)*

₩331,360.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 12월 22일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩331,360.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
215-5030
제조사 부품 번호:
D4GS-N4R-5
제조업체:
Omron
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Omron

Lock Style

Keyed

Product Type

Safety Rated Interlock Switch

Lock Type

Key

Actuator Included

No

Safety Contacts

1 NO/1 NC

Housing Material

Plastic

Series

D4GS

Minimum Operating Temperature

-30°C

Contact AC Voltage

240V ac

Contact DC Voltage

250V

Switch Contact Current

2.5A

IP Rating

IP67

Hazardous Area Certification

No

Maximum Operating Temperature

70°C

Length

85mm

Number of Head Directions

1

Depth

85mm

Width

30mm

Standards/Approvals

UL, CQC

Omron D4GS Series Safety Rated Interlock Switch, 240V Contact AC Voltage, 1 NO/1 NC Safety Contacts - D4GS-N4R-5


This safety-rated interlock switch is a Compact keyed device intended to monitor and lock access to guards and doors in industrial systems. It is designed for applications requiring a keyed lock mechanism and direct-opening safety contacts to interrupt hazardous machinery circuits. The unit is constructed from plastic with a sealed main body for use where ingress resistance is required and is suited to control circuits in automation and electrical installations.

Features & Benefits


• 1NO/1NC contact set provides safety and auxiliary functions
• IP67 main-body protection enables use in wet conditions
• Operates across -30 to 70°C for varied ambient temperatures
• Rated for AC 240V and DC 250V to suit control voltages
• Contact current capacity of 2.5A supports modest loads

**Applications**


• Suitable for guarding on automated presses and conveyors
• Ideal for safety monitoring on enclosure doors in production lines
• Used with programmable controllers for machine interlocking inputs
• Can be used for access control on maintenance hatches in plants

What mounting orientations are possible with this product?


It supports both front and rear mounting to accommodate confined or variable installation spaces.

How does the key Interface tolerate mechanical shock and vibration?


The operating key features a rubber-mounted hole to absorb vibration and reduce impact transmission to the switch head.

How is cable connection handled for field wiring?


The unit is supplied with a multi-core cable (UL2464, AWG22) finished to an o.d. of 7.2 mm and requires unused cores to be cut back to the outer sheath during installation.

What electrical protection is recommended for short-circuit conditions?


Use a gI or gG fuse sized according to IEC 60269 recommendations when operating to EN ratings and calculate breaking capacity at 150–200% of rated current.

관련된 링크들