SICK FXL1 Series Safety Controller, 2 Safety Outputs, 24V dc

Subtotal (1 unit)*

₩943,200.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 11월 09일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩943,200.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-9512
제조사 부품 번호:
FXL1-SPBUSA00
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Safety Controller

Series

FXL1

Number of Safety Outputs

2

Safety Category

4

Supply Voltage

24V dc

Contact Current

100mA

Terminal Type

M12 Connector

Width

40mm

Length

194.4mm

Depth

45mm

IP Rating

IP65, IP69K, IP67

COO (Country of Origin):
MY

SICK FXL1 Series Safety Controller, 24V DC Supply Voltage, 2 Safety Outputs - FXL1-SPBUSA00


This safety controller provides monitored semiconductor safety outputs and diagnostics for machinery protection in industrial environments. Designed for use with plug-in M12 connections, it delivers safety-related switching and actuator monitoring while tolerating demanding ambient conditions. The unit supports safe series wiring and options for in-cabinet or field connection schemes, delivering dependable lock monitoring and application diagnostic signalling.

Features and Benefits:


• SIL3 safety integrity level enabling high-risk applications
• Category4 safety classification supporting interlocking monitoring
• Dual PNP OSSD outputs providing cross-circuit monitored protection
• ≤100mA output current limiting compatible with small loads
• IP65 IP67 IP69K enclosure rating allowing washdown environments

Applications


• Suitable for guarding and interlock monitoring on production lines
• Used with electromechanical safety locks requiring monitored outputs
• Ideal for safe series connections with Flexi Loop diagnostics
• Can be used for machine door locking monitoring and control

What power range is required for operation?


It requires a 24V DC supply within 19.2V DC to 28.8V DC.

How are the field connections implemented?


Connections use an 8-pin M12 plug connector with stainless-steel coupling.

What diagnostic signals are available?


It provides an auxiliary application diagnostic output Plus LEDs for status and diagnostics.

How fast does the device respond and release?


Response time is ≤150ms and release time is ≤350ms with increased series-connection delay per additional switch.