SICK FX3 Series Safety Controller, 96 Safety Inputs, 48 Safety Outputs, 24V dc
- RS 제품 번호:
- 701-9196
- Distrelec 제품 번호:
- 304-01-241
- 제조사 부품 번호:
- FX3-CPU000000
- 제조업체:
- SICK
Subtotal (1 unit)*
₩565,714.50
재고있음
- 11 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩565,714.50 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 701-9196
- Distrelec 제품 번호:
- 304-01-241
- 제조사 부품 번호:
- FX3-CPU000000
- 제조업체:
- SICK
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | SICK | |
| Series | FX3 | |
| Product Type | Safety Controller | |
| Number of Safety Inputs | 96 | |
| Number of Safety Outputs | 48 | |
| Safety Category | 4 | |
| Mount Type | DIN Rail | |
| Supply Voltage | 24V dc | |
| Number of I/Os | 3 | |
| Contact Current | 4A | |
| Contact Voltage | 24V dc | |
| Width | 120.8mm | |
| Standards/Approvals | CE, UL | |
| Length | 96.5mm | |
| Depth | 120.6mm | |
| Terminal Type | Spring Terminal | |
| IP Rating | IP20 | |
| 모두 선택 | ||
|---|---|---|
브랜드 SICK | ||
Series FX3 | ||
Product Type Safety Controller | ||
Number of Safety Inputs 96 | ||
Number of Safety Outputs 48 | ||
Safety Category 4 | ||
Mount Type DIN Rail | ||
Supply Voltage 24V dc | ||
Number of I/Os 3 | ||
Contact Current 4A | ||
Contact Voltage 24V dc | ||
Width 120.8mm | ||
Standards/Approvals CE, UL | ||
Length 96.5mm | ||
Depth 120.6mm | ||
Terminal Type Spring Terminal | ||
IP Rating IP20 | ||
SICK FX3 Series Safety Controller, 96 Safety Inputs, 48 Safety Outputs - FX3-CPU000000
This safety controller is a compact, DIN-rail mounted device designed to supervise and manage machine safety functions within industrial automation systems. It operates on a 24V supply and integrates with a programmable safety system to process high-density safety I/O for complex machinery. The unit suits environments requiring category 4 safety performance and supports configuration and diagnostics via an RS-232 interface.
Features & Benefits
• 96 safety inputs enabling extensive sensor coverage for large machines
• 48 safety outputs providing numerous controlled stop or safe-state actions
• Category 4 performance delivering the highest architectural safety level
• 24V DC operation with 4A supply-current limitation ensuring predictable power design
• Spring-terminal connections allowing secure, tool-free wiring retention
• 48 safety outputs providing numerous controlled stop or safe-state actions
• Category 4 performance delivering the highest architectural safety level
• 24V DC operation with 4A supply-current limitation ensuring predictable power design
• Spring-terminal connections allowing secure, tool-free wiring retention
**Applications**
• Suitable for safeguarding multi-axis robotic workcells with many sensors
• Ideal for central safety logic in automated production lines
• Used with safety gate and light curtain networks requiring many inputs
• Can be used for coordinated emergency-stop handling across plant zones
• Ideal for central safety logic in automated production lines
• Used with safety gate and light curtain networks requiring many inputs
• Can be used for coordinated emergency-stop handling across plant zones
What environmental conditions can it tolerate in operation?
It is specified for operation between −25°C to +55°C and for non-condensing humidity of 10%–95% while housed in an IP20 enclosure.
How is configuration and offline access achieved?
Configuration and diagnostics are provided through an RS-232 M8 female connector, 4-pin Interface for connection to programming tools.
What mechanical mounting and form factor should planners allow for?
The unit mounts to a standard DIN rail and has a narrow module width suitable for Compact control cabinets.
How is system configuration preserved and powered within the safety system?
System configuration and central supply functions require a separately ordered system plug which also services system-level storage and power distribution.
What protection class and electrical categories are relevant for installation planning?
The device conforms to protection class III and overvoltage category II, with switch-on times up to 18s to consider during power sequencing.
Note
The system memory plug (FX3-MPL) is sold separately
관련된 링크들
- SICK FX0 Series Safety Controller, 5 Safety Inputs, 5 Safety Outputs
- SICK FX0 Series Safety Module, 1 Inputs, 2 Outputs, 24V dc
- SICK FX3 Series Safety Controller, 24V dc
- Pilz PNOZmulti Mini Series Safety Controller, 20 Safety Inputs, 4 Safety Outputs, 24V dc
- SICK FX0 Series Safety Module, 1 Inputs, 5 Outputs, 24V dc
- ABB Pluto Series Safety Controller, 36 Safety Inputs, 6 Safety Outputs, 24V dc
- Pilz Safety Controller, 2 Safety Inputs, 4 Safety Outputs, 24V
- Pilz Safety Controller, 32 Safety Inputs, 32 Safety Outputs, 24V