Telemecanique Sensors XY2CE Rope Pull Switch 229 mm, 2 NO/2 NC
- RS 제품 번호:
- 130-0882
- 제조사 부품 번호:
- XY2CE1A290
- 제조업체:
- Telemecanique Sensors
현재 비가용
죄송합니다. 언제 재입고될지 모릅니다.
- RS 제품 번호:
- 130-0882
- 제조사 부품 번호:
- XY2CE1A290
- 제조업체:
- Telemecanique Sensors
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Telemecanique Sensors | |
| Product Type | Rope Pull Switch | |
| Contact Configuration | 2 NO/2 NC | |
| IP Rating | IP66 | |
| Number of Cable Entries | 3 | |
| Series | XY2CE | |
| Minimum Operating Temperature | -25°C | |
| Contact DC Voltage | 250V dc | |
| Contact AC Voltage | 240V ac | |
| E-Stop Button | Yes | |
| Reset Button | Yes | |
| Maximum Operating Temperature | 70°C | |
| Width | 105mm | |
| Standards/Approvals | UL (NISD), CSA C 22-2, EAC, CSA, CCC, EN/IEC 60947-5-5, UL 508 | |
| Depth | 142mm | |
| Length | 229mm | |
| Housing Material | Stainless Steel | |
| Hazardous Area Certification | ATEX | |
| Mechanical Life | 60000Cycles | |
| Conduit Entry | M20 | |
| 모두 선택 | ||
|---|---|---|
브랜드 Telemecanique Sensors | ||
Product Type Rope Pull Switch | ||
Contact Configuration 2 NO/2 NC | ||
IP Rating IP66 | ||
Number of Cable Entries 3 | ||
Series XY2CE | ||
Minimum Operating Temperature -25°C | ||
Contact DC Voltage 250V dc | ||
Contact AC Voltage 240V ac | ||
E-Stop Button Yes | ||
Reset Button Yes | ||
Maximum Operating Temperature 70°C | ||
Width 105mm | ||
Standards/Approvals UL (NISD), CSA C 22-2, EAC, CSA, CCC, EN/IEC 60947-5-5, UL 508 | ||
Depth 142mm | ||
Length 229mm | ||
Housing Material Stainless Steel | ||
Hazardous Area Certification ATEX | ||
Mechanical Life 60000Cycles | ||
Conduit Entry M20 | ||
- COO (Country of Origin):
- MA
Telemecanique XY2CE & XY2CB Emergency Stop Rope Pull Switches
These emergency stop trip wire switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. They can be tripped by a single human action when a normal emergency stop function is not available and will also trip in the event of the trip wire breaking.
Switches incorporate positive opening operation contacts, the tripping of the switch being made with positive action
The switch latches in the tripped position (N/C safety contact(s) open). The function of the N/O contact is purely for signalling
Incorporates a reset button, which re-closes the safety contact(s), restarting of the machine must only be achieved by manual operation of a control device within the machine start circuit, remote to the trip wire switch
Recommended distance between cable supports is 15m (for model XY2-CB30 a distance of 20m is recommended)
The XY2 CE1A296 comes with a pilot light (direct supply)
Note
The XY2 CB switch must not be used if the installation requires that the trip wire be angled but the XY2 CE switch can. In this case, the total sum of the angles through which the trip wire bends must not exceed 180°.
Standards
EN/ISO 13850:2006
관련된 링크들
- Telemecanique Sensors XY2CE Rope Pull Switch 229 mm, 2 NO/2 NC
- Telemecanique Sensors XY2CE Rope Pull Switch 229 mm, 2 NC
- Telemecanique Sensors XY2CE Rope Pull Switch 229 mm, 1 NO/1 NC
- Telemecanique Sensors XY2 Rope Pull Switch 229 mm, Left Side, 2 NO/2 NC
- Telemecanique Sensors XY2 Rope Pull Switch 229 mm, Right Side, 2 NO/2 NC
- Telemecanique Sensors XY2CE Rope Pull Switch 285 mm, 2 NO/2 NC
- Telemecanique Sensors XY2 Rope Pull Switch 229 mm, Right Side, 1 NO/1 NC
- Telemecanique Sensors XY2-CE Rope Pull Switch 5.6 in, Right Side, 2 NO/2 NC