ABB Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type
- RS 제품 번호:
- 201-6959
- 제조사 부품 번호:
- 2CSR275180R1165 DS201 M B16 A30
- 제조업체:
- ABB
Subtotal (1 unit)*
₩215,650.50
현재 액세스할 수 없는 재고 정보 - 나중에 다시 확인해 주세요.
수량 | 한팩당 |
|---|---|
| 1 + | ₩215,650.50 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 201-6959
- 제조사 부품 번호:
- 2CSR275180R1165 DS201 M B16 A30
- 제조업체:
- ABB
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | ABB | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Current Rating | 16A | |
| Number of Poles | 2 | |
| Range | System Pro M Compact | |
| Series | DS201 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type B | |
| Mount Type | DIN Rail | |
| Rated AC Voltage | 240V ac | |
| Terminal Type | Screw | |
| Earth Leakage Protection Type | Type A | |
| Width | 35mm | |
| Height | 85mm | |
| Depth | 69mm | |
| Standards/Approvals | CCC, CSA, UL | |
| Tripping Mechanism | Thermal Magnetic | |
| Breaking Capacity | 10kA | |
| 모두 선택 | ||
|---|---|---|
브랜드 ABB | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Current Rating 16A | ||
Number of Poles 2 | ||
Range System Pro M Compact | ||
Series DS201 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type B | ||
Mount Type DIN Rail | ||
Rated AC Voltage 240V ac | ||
Terminal Type Screw | ||
Earth Leakage Protection Type Type A | ||
Width 35mm | ||
Height 85mm | ||
Depth 69mm | ||
Standards/Approvals CCC, CSA, UL | ||
Tripping Mechanism Thermal Magnetic | ||
Breaking Capacity 10kA | ||
ABB RCBO, 230V Rated Voltage, 10kA Rated Short-Circuit Capacity - DS201 Series - 2CSR275180R1165 DS201 M B16 A30
Looking for a complete solution to protect your single-phase electrical networks? This 2-pole RCBO from ABB immediately interrupts power supplies to help prevent damage caused by overloads and short circuits. It also safeguards against earth fault currents for improved safety. You can easily identify earth problems, thanks to the blue flag status indicator. The small unit has dimensions of 69 (L) x 35 (W) x 85mm (D), so takes up little space on crowded distribution boards. A robust plastic housing with an IP40 rating is on hand to protect against damage caused by tools and wires greater than 1mm.
Features & Benefits
• Wide operating temperature range between -25°C and +55°C for use in demanding conditions
• Mechanical endurance of 20,000 cycles for reliable performance
• Toggle switch for easy resetting
Applications
• Automated manufacturing processes
• Industrial pumps
• Electrical networks
• Computer rooms
What's the current rating of this RCBO?
It has a current rating of 16A, so can handle heavy-duty applications.
What are the connection sizes and specifications of this RCBO?
This RCBO has failsafe bi-directional cylinder-lift screw terminals. It has a connecting capacity for 10/10mm² busbar cables, 16mm² flexible cables and 25mm² stranded cables, so you can set it up according to your system's needs.
관련된 링크들
- ABB Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type
- ABB Residual Current Circuit Breaker with Overload Protection, 6A Current Rating, 1-Pole, 30 mA Trip Sensitivity, Type
- ABB Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 30 mA Trip Sensitivity, Type
- ABB Residual Current Circuit Breaker with Overload Protection, 10A Current Rating, 2-Pole, 10 mA Trip Sensitivity, Type
- ABB Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 3-Pole, 30 mA Trip Sensitivity, Type
- ABB Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 4-Pole, 30 mA Trip Sensitivity, Type
- ABB Residual Current Circuit Breaker with Overload Protection, 40A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type
- ABB Residual Current Circuit Breaker with Overload Protection, 20A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type