Siemens RCBO, 6A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type C, Sentron Range
- RS 제품 번호:
- 150-4183
- 제조사 부품 번호:
- 5SU1354-7KK06
- 제조업체:
- Siemens
Subtotal (1 unit)*
₩114,586.00
재고있음
- 7 개 단위 배송 준비 완료
- 추가로 2026년 1월 28일 부터 5 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩114,586.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS 제품 번호:
- 150-4183
- 제조사 부품 번호:
- 5SU1354-7KK06
- 제조업체:
- Siemens
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Siemens | |
| Current Rating | 6A | |
| Range | Sentron | |
| Number of Poles | 2 | |
| Trip Sensitivity | 30mA | |
| Circuit Breaker Type | RCBO | |
| Series | 5SU1 | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 230V | |
| Mounting Style | DIN Rail Mount | |
| Better World Product | Yes | |
| Better World Claim | Extended product life | |
| Overall Depth | 76.2mm | |
| Terminal Contact Type | Screw | |
| Overall Width | 90mm | |
| Overall Dimensions | 35.4 x 90 x 76.2mm | |
| Break Time | Instantaneous | |
| Overall Length | 35.4mm | |
| Reset Actuator Type | Toggle Switch | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA, 35 kA | |
| 모두 선택 | ||
|---|---|---|
브랜드 Siemens | ||
Current Rating 6A | ||
Range Sentron | ||
Number of Poles 2 | ||
Trip Sensitivity 30mA | ||
Circuit Breaker Type RCBO | ||
Series 5SU1 | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 230V | ||
Mounting Style DIN Rail Mount | ||
Better World Product Yes | ||
Better World Claim Extended product life | ||
Overall Depth 76.2mm | ||
Terminal Contact Type Screw | ||
Overall Width 90mm | ||
Overall Dimensions 35.4 x 90 x 76.2mm | ||
Break Time Instantaneous | ||
Overall Length 35.4mm | ||
Reset Actuator Type Toggle Switch | ||
Breaking Capacity at Maximum Voltage Rating 10 kA, 35 kA | ||
- COO (Country of Origin):
- RO
Siemens SENTRON RCBO, 2 Pole, 30mA Trip Sensitivity - 5SU1 Series - 5SU1354-7KK06
This RCBO (residual current breaker with over-current) from Siemens' SENTRON range combines two kinds of protection in one slim design. Residual current detection breaks the circuit in case of leakage, while overload protection guards against overheating. This breaker will also trip if it detects pulsating residual DC (direct current), ensuring the safety of both equipment and personnel. With a trip sensitivity of 30mA (milliamperes), this breaker provides robust detection and security so your operations can continue in confidence.
• Toggle switch reset actuator for ease of use
• Screw connections attach to the terminal contact for quick and easy installation
• Double-pole design for greater capacity
• Instantaneous break time for safety in your workplace
• Screw connections attach to the terminal contact for quick and easy installation
• Double-pole design for greater capacity
• Instantaneous break time for safety in your workplace
Does this circuit breaker offer fire protection?
Yes, this breaker's current protection does include fire protection. In addition, it easily connects to Siemens' arc-fault detection units for enhanced safety.
Where should this breaker be mounted?
This circuit breaker conforms to DIN rail standards, so it's easy to mount with complex tools and provides optimal organisation as well as convenient access.
관련된 링크들
- Siemens RCBO, 6A Current Rating, 2P Poles, 30mA Trip Sensitivity, SENTRON Range
- Siemens RCBO, 10A Current Rating, 2P Poles, 30mA Trip Sensitivity, Sentron Range
- Siemens RCBO, 16A Current Rating, 2P Poles, 30mA Trip Sensitivity, Sentron Range
- Siemens RCBO, 13A Current Rating, 2P Poles, 30mA Trip Sensitivity, Sentron Range
- Siemens RCBO, 32A Current Rating, 2P Poles, 30mA Trip Sensitivity, Sentron Range
- Siemens RCBO, 40A Current Rating, 2P Poles, 30mA Trip Sensitivity, SENTRON Range
- Siemens RCBO, 20A Current Rating, 2P Poles, 30mA Trip Sensitivity, SENTRON Range
- Siemens RCBO, 16A Current Rating, 1P Poles, 30mA Trip Sensitivity, SENTRON Range