RS Better World
Siemens Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 2-Pole, 30 mA Trip Sensitivity,
- RS 제품 번호:
- 211-9610
- 제조사 부품 번호:
- 5SU1354-4KK16
- 제조업체:
- Siemens
Subtotal (1 unit)*
₩435,940.00
일시적 품절
- 2026년 11월 19일 부터 3 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩435,940.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
Our Better World range features products that make it easy for you to make a greener product choice you can trust.
Learn more about RS Better World products
- RS 제품 번호:
- 211-9610
- 제조사 부품 번호:
- 5SU1354-4KK16
- 제조업체:
- Siemens
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Siemens | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Current Rating | 16A | |
| Series | 5SU1 | |
| Range | SENTRON | |
| Number of Poles | 2 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Class C | |
| Rated AC Voltage | 230V ac | |
| Terminal Type | Screw | |
| Width | 36mm | |
| Height | 90mm | |
| Depth | 77mm | |
| Better World Product | Yes | |
| Better World Claim | Extended Product Life | |
| Breaking Capacity | 10kA | |
| Standards/Approvals | No | |
| 모두 선택 | ||
|---|---|---|
브랜드 Siemens | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Current Rating 16A | ||
Series 5SU1 | ||
Range SENTRON | ||
Number of Poles 2 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Class C | ||
Rated AC Voltage 230V ac | ||
Terminal Type Screw | ||
Width 36mm | ||
Height 90mm | ||
Depth 77mm | ||
Better World Product Yes | ||
Better World Claim Extended Product Life | ||
Breaking Capacity 10kA | ||
Standards/Approvals No | ||
- COO (Country of Origin):
- RO
Siemens 5SU1 Series Residual Current Circuit Breaker With Overload Protection, 16A Current, 30mA Trip sensitivity - 5SU1354-4KK16
This residual current circuit-breaker with overload protection provides combined earth-leakage and overcurrent protection for single-phase installations at 230 V. It is designed for installation on DIN rail and suits distribution boards where compact, modular protective devices are required. The device operates with AC supply at 50/60 Hz and incorporates a neutral-switching function and touch protection for safer handling during installation and maintenance.
Features and Benefits:
• 10 kA breaking capacity offers fault interruption performance
• 30 mA trip sensitivity reduces risk from residual currents
• Class C tripping characteristic handles moderate inrush currents
• 16 A rated operational current supports common circuit loads
• Screw terminals accept up to 35 mm² conductors for secure connections
• 30 mA trip sensitivity reduces risk from residual currents
• Class C tripping characteristic handles moderate inrush currents
• 16 A rated operational current supports common circuit loads
• Screw terminals accept up to 35 mm² conductors for secure connections
Applications
• Suitable for domestic ring and radial circuit protection
• Used for circuits requiring combined earth-fault and overload protection
• Suitable for installations needing a Compact DIN-rail device
• Can be used where neutral-conductor switching is required
• Used for circuits requiring combined earth-fault and overload protection
• Suitable for installations needing a Compact DIN-rail device
• Can be used where neutral-conductor switching is required
What ambient temperature range can it operate within?
It can operate between -25 °C and 55 °C.
How does the device perform under short-circuit conditions?
It provides a short-circuit breaking capacity of 10 kA according to EN 61009-1 and 20 kA per IEC 60947-2.
What conductor types and sizes are supported by the terminals?
Solid and stranded conductors from 0.75 mm² up to 35 mm² are supported, with finely stranded up to 25 mm² when using ferrules.
How is the product tested for lower supply voltages?
The minimum voltage for testing equipment is 195 V and the rated insulation voltage is 264 V.
What mechanical lifecycle can be expected from operation?
The typical mechanical service life is 10,000 operating cycles.
관련된 링크들
- Siemens Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 2-Pole, 30 mA Trip Sensitivity,
- Siemens Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 1-Pole, 30 mA Trip Sensitivity,
- Siemens Residual Current Circuit Breaker with Overload Protection, 6A Current Rating, 2-Pole, 30 mA Trip Sensitivity,
- Siemens Residual Current Circuit Breaker with Overload Protection, 32A Current Rating, 2-Pole, 30 mA Trip Sensitivity,
- Siemens Residual Current Circuit Breaker with Overload Protection, 25A Current Rating, 2-Pole, 30 mA Trip Sensitivity,
- Siemens Residual Current Circuit Breaker with Overload Protection, 20A Current Rating, 2-Pole, 30 mA Trip Sensitivity,
- Siemens Residual Current Circuit Breaker with Overload Protection, 10A Current Rating, 2-Pole, 30 mA Trip Sensitivity,
- Siemens Residual Current Circuit Breaker with Overload Protection, 8A Current Rating, 2-Pole, 30 mA Trip Sensitivity,