Tele Process Pump Controller, 250 V ac, +55°C
- RS 제품 번호:
- 182-9996
- 제조사 부품 번호:
- G2ASMA20
- 제조업체:
- Tele
Subtotal (1 unit)*
₩299,155.00
재고있음
- 4 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩299,155.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 182-9996
- 제조사 부품 번호:
- G2ASMA20
- 제조업체:
- Tele
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Tele | |
| Supply Voltage | 250 V ac | |
| IP Rating | IP20, IP40 | |
| Maximum Fluid Temperature | +55°C | |
| 모두 선택 | ||
|---|---|---|
브랜드 Tele | ||
Supply Voltage 250 V ac | ||
IP Rating IP20, IP40 | ||
Maximum Fluid Temperature +55°C | ||
- COO (Country of Origin):
- AT
Pump control, Alternating/parallel
Alternated access of two pumps or other devices
Even distribution of duty
Parallel duty at high demand
Operation using 1 or 2 input signals (two modes of operation)
Timing offset of the two loads to avoid water hammer effcects
Supply voltage selectable via TR2 power modules
2 separate change over relays for device control
Width 22.5mm
Industrial design
Task
Two pumps are installed at a sewage pumping station that are to be run alternately for equal periods to ensure equal wear.
Solution
The pump switchover system activates the pumps alternately, if needed, the second pump can also be activated so that both run at the same time (parallel operation)
Use/value
Equal wear, and therefore longer service intervals for both pumps
Minimised pump failures through nearly equal number of operating hours
Peak load coverage
Zero-voltage safety in the event of power failures
Applications
Centrifugal Pumps
Sewage Pumps
Water & Waste
Even distribution of duty
Parallel duty at high demand
Operation using 1 or 2 input signals (two modes of operation)
Timing offset of the two loads to avoid water hammer effcects
Supply voltage selectable via TR2 power modules
2 separate change over relays for device control
Width 22.5mm
Industrial design
Task
Two pumps are installed at a sewage pumping station that are to be run alternately for equal periods to ensure equal wear.
Solution
The pump switchover system activates the pumps alternately, if needed, the second pump can also be activated so that both run at the same time (parallel operation)
Use/value
Equal wear, and therefore longer service intervals for both pumps
Minimised pump failures through nearly equal number of operating hours
Peak load coverage
Zero-voltage safety in the event of power failures
Applications
Centrifugal Pumps
Sewage Pumps
Water & Waste
관련된 링크들
- Sensata Cynergy3 Process Pump Controller, 250 V ac, +45°C
- Xylem Process Pump Controller for Standard Liquid Pump, 415 V ac
- Sensata Cynergy3 Process Pump Controller for Hydromatic, 240 V ac, +60°C
- RS PRO Process Pump Controller for Brushless Micropump, 6 → 28V, +80°C
- RS PRO Process Pump Controller for Brushless Micropump, 6 → 28V
- Xylem Lowara Process Pump Controller for Diaphragm, 220 V, 240 V, +60°C
- RS PRO Process Pump Controller for Brushless Micropump, 6 → 28 V dc
- Pump Controllers