Festo HGL-1/8-QS-4 Check Valve, 10 bar Tube Threaded

Subtotal (1 unit)*

₩81,000.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 10월 19일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩81,000.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
202-3568
Distrelec 제품 번호:
301-68-821
제조사 부품 번호:
HGL-1/8-QS-4
제조업체:
Festo
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Festo

Product Type

Check Valve

Inlet Connection Type

Tube

Outlet Connection Type

Threaded

Series

HGL-1/8-QS-4

Minimum Operating Pressure

0.5bar

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

60°C

Standards/Approvals

ISO8573-1:2010, RoHS

Maximum Operating Pressure

10 bar

COO (Country of Origin):
IN

Festo HGL-1/8-QS-4 Series Check Valve, 10 Bar Maximum Operating Pressure, -10°C Minimum Operating Temperature - HGL-1/8-QS-4


This check valve provides one-way flow control for pneumatic systems, connecting a tube inlet to a threaded outlet. It is designed for inline installation where compact size and straightforward flow prevention are required. The component operates within typical industrial pneumatic conditions and aligns with recognised quality standards.

Features and Benefits:


• Maximum operating pressure 10 bar enables higher-pressure applications
• Minimum operating pressure 0.5 bar ensures function at low supply pressures
• Operational temperature range -10°C to 60°C supports varied environments
• Tube inlet and threaded outlet allow simple tube-to-threaded connections
• Conforms to ISO 8573-1:2010 for maintained air quality parameters
• RoHS compliant construction limits restricted substances

Applications


• Suitable for machine pneumatic supply line protection
• Ideal for preventing reverse flow in pneumatic actuators
• Used with compressed-air distribution manifolds in factories
• Can be used for pilot lines in control valves
• Appropriate for compact pneumatic assemblies requiring inline valves

What connection types does it use for integration?


The component accepts tubing at the inlet and provides a threaded outlet for direct mating with standard threaded ports.

How does temperature influence operation limits?


Performance is maintained within the stated -10°C to 60°C band

outside this range material properties and sealing can be compromised.

Which pressure conditions will prevent proper sealing?


If system pressure falls below 0.5 bar the check mechanism may not actuate reliably and reverse flow could occur.

How does compliance affect installation in regulated facilities?


Conformance to the cited standard and RoHS supports specification for installations requiring controlled air quality and restricted-substance considerations.