Gossen Metrawatt M694B PAT Tester, Electrical, Medical, Welding Test Type

Subtotal (1 unit)*

₩13,695,040.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 추가로 2026년 11월 04일 부터 1 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩13,695,040.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
645-154
제조사 부품 번호:
M694B
제조업체:
Gossen Metrawatt
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Gossen Metrawatt

Product Type

PAT Tester

Tester Type

Safety Tester

Test Type

Electrical, Medical, Welding

Flash Test

Yes

Model Number

M694B

Power Source

230 V ac

Minimum Supply Voltage

90V ac

Minimum Operating Temperature

0°C

Maximum Operating Temperature

40°C

Standards/Approvals

IEC 62353, EN 50678, IEC 61000-3-2 B, VDE 0702, EN 62368, EN 61000-4-8, VDE 0544-4, DIN EN 61326-1, EN 61000-4-2, DIN EN 61326-2-2, EN 60974-4, EN 61000-4-11, EN 61000-4-3, EN 62911, SNR 462638, EN 61000-4-4, IEC 61000-3-3 B, EN 62353, IEC 60974-4, VDE 0701, VDE 0868-1, IEC 62911, EN 61000-4-6, VDE 0751-1, NEN 3140, VDE 0868-911, ÖVE E 8701, EN 50699, IEC 62368, EN 61000-4-5, EN 55011 B

Maximum Supply Voltage

264V ac

COO (Country of Origin):
DE

Gossen-Metrawatt Pat Tester, 230V Power Source, 90 to 264V Supply Voltage - M694B


This PAT tester is a safety testing instrument designed for evaluation of electrical, medical and welding equipment across varied supply conditions. It operates from standard mains and accommodates a broad input range suited to diverse site voltages. The unit is intended for routine verification and functional safety assessments where portable safety testing is required.

Features and Benefits:


• *Made in Germany
• 90 to 264V Supply Voltage ensures operation on varied mains supplies
• 230V Power Source provides standard mains compatibility
• IEC 62353 compliance supports medical equipment safety testing
• IEC 60974-4 alignment enables welding equipment assessments
• VDE 0702 conformity facilitates electrical appliance inspections

Applications


• Used for periodic checks of medical devices in maintenance departments
• Suitable for safety verification of welding machines on site
• Can be used for portable PAT testing across varied work sites

What environmental limits affect on-site use?


It functions within an ambient range from 0°C to 40°C.

Which standards enable its use with electrical appliances?


It meets VDE 0702 and relevant EN and IEC standards required for appliance testing.

Is it appropriate for medical equipment assessments?


Yes, it adheres to IEC 62353 enabling tests specific to medical device safety.

Can it handle interference and immunity conditions in industrial settings?


The unit complies with multiple EN/IEC electromagnetic compatibility standards covering immunity and emissions.