Eaton XDP DOL Starter, DOL, 230V ac, 4 kW, 3 Phase, IP65

본 이미지는 참조용이오니 재확인이 필요하시면 문의해주세요.

Subtotal (1 unit)*

₩536,080.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 1 개 단위 배송 준비 완료
  • 추가로 2026년 9월 29일 부터 10 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩536,080.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
528-7353
제조사 부품 번호:
118522 XDP4/I(230V50HZ,240V60HZ)
제조업체:
Eaton
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Eaton

Product Type

DOL Starter

Power Rating

4kW

Sub Type

DOL

Number of Phases

3

Mount Type

Surface

IP Rating

IP65

Number of Poles

3

Overall Length

200mm

Maximum Voltage

230V ac

Standards/Approvals

No

Overall Width

120mm

Hazardous Area Certification

No

Overall Depth

160mm

Series

XDP

제외

COO (Country of Origin):
GB

EATON XDP DOL Starter Series with Isolator


Providing reliability and long operating life, these 'direct-on-line' starters are totally insulated with IP65 protection. Capable of high numbers of operations, these starters are constructed from standard components meaning they are very easy to maintain. Fitted with AC-3 rated triple pole contactor, AC-3 rated triple pole switch disconnector and on and off pushbuttons, these devices also allow for 3 padlocks for additional safety.

All starters in this range are wired to accept EATON overload relays for overload protection, also available from RS components to be purchased separately.

4 & 5.5kW models = H200 x W120 x D160mm, 7.5 & 11kW models = H240 x W160 x D160mm

Features and Benefits:


• Fitted with metric knockouts

• Easy maintenance

• Complies with IEE regulations

• 16th edition on isolation and switching

• Glass fibre reinforced polycarbonate casing

Applications:


Used for starting 3 phase induction motors, direct on line starters are regularly used in industrial applications such as conveyor belts, compressors and small water pumps.

What is the difference between dol and star delta starters?


Both devices are used to start induction motors however, where partial voltage is applied to each winding of a star delta starter, a DOL has 100% voltage applied. This also applies to the current, a star delta uses one-third of the starting current that a DOL does. Direct on line starters are the most common and simplest starting method, within a motor start-up they also provides the lowest temperature rise. Star delta starters allow for starting the motor at a lower voltage, making them suitable for high inertias.

Note

FLC figures quoted are maximum, other overload ratings can be used dependant on FLC rating.

Standards

IEC/EN 60529, DIN 43660, EN 50262