ABB Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 90 → 170V ac, DIN Rail

본 이미지는 참조용이오니 재확인이 필요하시면 문의해주세요.

Subtotal (1 unit)*

₩387,712.40

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 5월 04일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩387,712.40

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
775-8040
제조사 부품 번호:
1SVR740885R1300 CM-MPS.11P
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Monitoring Application

Phase, Voltage

Electrical Phase

3

Voltage Sensing Range

90 → 170V ac

Contact Configuration

DPDT

Voltage Sensitivity

Overvoltage, Undervoltage

Mounting Type

DIN Rail

Phase Sensitivity

NEUTRAL, Phase Failure, Phase Imbalance, Phase Sequence

Time Delay

0.1 → 30 s, 0s

Frequency Sensing Range

45 → 65Hz

Series

CM-MPS

Height

85.6mm

Terminal Type

Push In

Length

103.7mm

Minimum Voltage Sensed

90V ac

Width

22.5mm

Minimum Operating Temperature

-25°C

Operating Temperature Range

+60°C

Maximum Operating Temperature

+60°C

Dimensions

103.7 x 22.5 x 85.6mm

Maximum Voltage Sensed

170V ac

COO (Country of Origin):
DE

CM-MPS x3 Multifunctional Three-Phase Monitoring Relays


The CM-MPSx3 are multifunctional monitoring relays for three-phase mains. They monitor the phase parameters phase sequence, phase failure, over- and undervoltage and phase unbalance. CM-MPS.23 also monitors the neutral for interruption. The threshold values for over and undervoltage and phase unbalance are adjustable. CM-MPS.23 is also suitable for monitoring single-phase mains. For this, all three external conductors (L1, L2, L3) have to be jumpered and connected as one single conductor. Phase sequence monitoring has to be deactivated and the threshold value for phase unbalance has to be set to the maximum (25 %).

Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over and undervoltage as well as phase unbalance
Automatic phase sequence correction configurable
Interrupted neutral monitoring possible with CM-MPS.23
CM-MPS.23 can also be used to monitor single-phase mains
Can be used for mains with a frequency of 45 to 440 Hz
Threshold values for phase unbalance, over- and undervoltage are adjustable as absolute values
Tripping delay can be adjusted or switched off by means of a logarithmic scale
ON-delayed or OFF-delayed tripping delay selectable
Powered by the measuring circuit
True RMS measuring principle
1x2 or 2x1 c/o (SPDT) contact configurable