사양
기술적 참조
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | ABB | |
| Monitoring Application | Phase, Voltage | |
| Electrical Phase | 3 | |
| Voltage Sensing Range | 180 → 280V ac | |
| Contact Configuration | DPDT | |
| Voltage Sensitivity | Overvoltage, Undervoltage | |
| Mounting Type | DIN Rail | |
| Phase Sensitivity | NEUTRAL, Phase Failure, Phase Imbalance, Phase Sequence | |
| Time Delay | 0.1 → 30 s, 0s | |
| Frequency Sensing Range | 45 → 65Hz | |
| Series | CM-MPS | |
| Maximum Operating Temperature | +60°C | |
| Operating Temperature Range | -25 → +60°C | |
| Minimum Operating Temperature | -25°C | |
| Maximum Voltage Sensed | 280V ac | |
| Width | 22.5mm | |
| Terminal Type | Screw | |
| Dimensions | 103.7 x 22.5 x 85.6mm | |
| Height | 85.6mm | |
| Length | 103.7mm | |
| Minimum Voltage Sensed | 180V ac | |
| Standards Met | UL | |
| 모두 선택 | ||
|---|---|---|
브랜드 ABB | ||
Monitoring Application Phase, Voltage | ||
Electrical Phase 3 | ||
Voltage Sensing Range 180 → 280V ac | ||
Contact Configuration DPDT | ||
Voltage Sensitivity Overvoltage, Undervoltage | ||
Mounting Type DIN Rail | ||
Phase Sensitivity NEUTRAL, Phase Failure, Phase Imbalance, Phase Sequence | ||
Time Delay 0.1 → 30 s, 0s | ||
Frequency Sensing Range 45 → 65Hz | ||
Series CM-MPS | ||
Maximum Operating Temperature +60°C | ||
Operating Temperature Range -25 → +60°C | ||
Minimum Operating Temperature -25°C | ||
Maximum Voltage Sensed 280V ac | ||
Width 22.5mm | ||
Terminal Type Screw | ||
Dimensions 103.7 x 22.5 x 85.6mm | ||
Height 85.6mm | ||
Length 103.7mm | ||
Minimum Voltage Sensed 180V ac | ||
Standards Met UL | ||
- COO (Country of Origin):
- DE
ABB CM-MPS Series Monitoring Relay, DPDT Contact Configuration, 180 to 280V AC Voltage Sensing Range - 1SVR730885R3300 CM-MPS.21S
This monitoring relay is a multifunctional device from the CM-MPS series, designed for effective monitoring in three-phase applications. With dimensions of 103.7 x 22.5 x 85.6mm, it operates within a voltage sensing range of 180-280 V AC and can handle electrical phases of up to three. The relay provides essential protection against voltage fluctuations and phase-related issues, ensuring system reliability.
Features & Benefits
• Monitors overvoltage and undervoltage conditions
• Detects phase imbalance and phase failure
• Adjustable tripping delay between 0 and 30 seconds
• Utilises DPDT contact configuration for versatile applications
• Suitable for mounting on standard DIN rails
• Wide operating temperature range from -25 to +60°C
• Detects phase imbalance and phase failure
• Adjustable tripping delay between 0 and 30 seconds
• Utilises DPDT contact configuration for versatile applications
• Suitable for mounting on standard DIN rails
• Wide operating temperature range from -25 to +60°C
Applications
• Used in industrial automation systems
• Suitable for three-phase electrical supply monitoring
• Employed in settings requiring phase sequence verification
• Ideal for needing neutral interruption detection
• Suitable for three-phase electrical supply monitoring
• Employed in settings requiring phase sequence verification
• Ideal for needing neutral interruption detection
How does the adjustable tripping delay enhance reliability in operations?
The adjustable tripping delay allows custom configuration between instantaneous and 30 seconds, enabling users to optimise the response time to faults without unnecessary interruptions. This ensures a fine balance between prompt action and avoiding nuisance tripping during transient conditions.
What are the key advantages of utilising a DPDT configuration?
The DPDT configuration offers flexibility by allowing two separate circuits to be managed simultaneously, providing enhanced control over monitoring and switching operations in various applications. This is particularly beneficial in complex systems where multiple conditions need to be monitored at once.
In which scenarios should the voltage sensitivity features be applied?
These voltage sensitivity features are crucial in environments prone to fluctuations, ensuring that equipment operates only within safe voltage limits. By monitoring both over and undervoltage events, it protects machinery from damage and enhances operational safety.
관련된 링크들
- ABB Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 90 → 170V ac, DIN Rail
- ABB Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 300 → 500V ac, DIN Rail
- ABB Phase Monitoring Relay, 3 Phase, DPDT, 300 → 500V ac, DIN Rail
- ABB Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 360 → 440V ac, DIN Rail
- ABB Phase Monitoring Relay, 3 Phase, DPDT
- ABB Phase Monitoring Relay, 3 Phase, DPDT, DIN Rail
- ABB Current Monitoring Relay, 1 Phase, DPDT, DIN Rail
- ABB Temperature Monitoring Relay, 1 Phase, DPDT, DIN Rail