Dold Frequency Monitoring Relay, SPDT, DIN Rail
- RS 제품 번호:
- 181-2793
- 제조사 부품 번호:
- MK9143N.38 +/-5Hz UH=DC24V tv=0-20s tan=0-30s
- 제조업체:
- Dold
Subtotal (1 unit)*
₩458,656.08
일시적 품절
- 2026년 1월 05일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩458,656.08 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 181-2793
- 제조사 부품 번호:
- MK9143N.38 +/-5Hz UH=DC24V tv=0-20s tan=0-30s
- 제조업체:
- Dold
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Dold | |
| Monitoring Application | Frequency | |
| Contact Configuration | SPDT | |
| Mounting Type | DIN Rail | |
| Time Delay | 0 → 20 s, 0 → 30s | |
| Frequency Sensing Range | ±5Hz | |
| Series | MK9143N | |
| Frequency Sensitivity | Overfrequency, Underfrequency | |
| Minimum Operating Temperature | -20°C | |
| Operating Temperature Range | +60°C | |
| Minimum Frequency Sensed | -5Hz | |
| Length | 97mm | |
| Maximum Frequency Sensed | +5Hz | |
| Maximum Operating Temperature | +60°C | |
| Terminal Type | Screw | |
| Dimensions | 97 x 22.5 x 90mm | |
| Width | 22.5mm | |
| Height | 90mm | |
| 모두 선택 | ||
|---|---|---|
브랜드 Dold | ||
Monitoring Application Frequency | ||
Contact Configuration SPDT | ||
Mounting Type DIN Rail | ||
Time Delay 0 → 20 s, 0 → 30s | ||
Frequency Sensing Range ±5Hz | ||
Series MK9143N | ||
Frequency Sensitivity Overfrequency, Underfrequency | ||
Minimum Operating Temperature -20°C | ||
Operating Temperature Range +60°C | ||
Minimum Frequency Sensed -5Hz | ||
Length 97mm | ||
Maximum Frequency Sensed +5Hz | ||
Maximum Operating Temperature +60°C | ||
Terminal Type Screw | ||
Dimensions 97 x 22.5 x 90mm | ||
Width 22.5mm | ||
Height 90mm | ||
- COO (Country of Origin):
- DE
Monitoring of local generator sets and voltage supplies
For precise frequency measuring with fast response time
High disturbance immunity
Separately adjustable trip points and separate outputs for over-
and under frequency (1 or 2 c/o each)
MK 9143N / MH 9143:
Trip points adjustable precisely and reproducible on 10 step rotational switch in the range of ± 0,1 Hz to ± 5 Hz related to 50 or 60 Hz
Nominal frequency 50 or 60 Hz selectable
Fixed hysteresis optimised for trip point
As option one common output for under and over frequency Window-mode (MK 9143N/400 / MH 9143/400)
Variable alarm value in the range of 45 to 65 Hz
Hysteresis adjustable for under- and over frequency separatelyadjustable 0 …20% Common output for under and over frequency Window-mode can be selected
Start up delay 0…30 s selectable
Manual or auto reset selectable
Output relay energized or de-energized on trip selectable for
over frequency
Output relay de-energized on trip for under frequency
Universal frequency measuring input for AC 40 … 550V
Several options for auxiliary supply
LED indicators for auxiliary supply, input frequency, over and
under frequency alarm
For precise frequency measuring with fast response time
High disturbance immunity
Separately adjustable trip points and separate outputs for over-
and under frequency (1 or 2 c/o each)
MK 9143N / MH 9143:
Trip points adjustable precisely and reproducible on 10 step rotational switch in the range of ± 0,1 Hz to ± 5 Hz related to 50 or 60 Hz
Nominal frequency 50 or 60 Hz selectable
Fixed hysteresis optimised for trip point
As option one common output for under and over frequency Window-mode (MK 9143N/400 / MH 9143/400)
Variable alarm value in the range of 45 to 65 Hz
Hysteresis adjustable for under- and over frequency separatelyadjustable 0 …20% Common output for under and over frequency Window-mode can be selected
Start up delay 0…30 s selectable
Manual or auto reset selectable
Output relay energized or de-energized on trip selectable for
over frequency
Output relay de-energized on trip for under frequency
Universal frequency measuring input for AC 40 … 550V
Several options for auxiliary supply
LED indicators for auxiliary supply, input frequency, over and
under frequency alarm
관련된 링크들
- Dold Frequency Monitoring Relay, SPDT, DIN Rail
- Dold Frequency Monitoring Relay, DPDT, 15 → 280V ac, DIN Rail
- Dold Thermistor Motor Protection Monitoring Relay, SPDT, DIN Rail
- Dold Monitoring Relay, SPDT, 24 → 400V ac/dc, DIN Rail
- Dold Monitoring Relay, SPDT, 24 → 240V ac/dc, DIN Rail
- Dold Insulation Monitoring Relay, SPDT, 0.8 → 1.1 V, DIN Rail
- Dold Multifunction Monitoring Relay, 3 Phase, SPDT, 24 → 400V ac, DIN Rail
- Dold Speed Monitoring Relay, SPDT, DIN Rail