Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 0.1A to 5A, 0V ac
- RS 제품 번호:
- 111-3093
- 제조사 부품 번호:
- K8DT-AS2TA
- 제조업체:
- Omron
Subtotal (1 unit)*
₩271,557.00
일시적 품절
- 2026년 8월 05일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩271,557.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 111-3093
- 제조사 부품 번호:
- K8DT-AS2TA
- 제조업체:
- Omron
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Omron | |
| Product Type | Monitoring Relay | |
| Electrical Phase | 1 | |
| Contact Configuration | SPST | |
| Mount Type | DIN Rail | |
| Minimum Current Sensed | 0.1A | |
| Power Consumption | 2.5VA | |
| Maximum Current Sensed | 5A | |
| Current Sensitivity | Overcurrent, Undercurrent | |
| Terminal Type | Push-in | |
| Time Delay | 250 ms | |
| IP Rating | IP20 | |
| Supply AC Voltage | 0V ac | |
| Minimum Operating Temperature | -20°C | |
| Relay Contact Current | 0.1, 5A | |
| Maximum Operating Temperature | 60°C | |
| Series | K8DT-AS | |
| Width | 17.5mm | |
| Length | 90mm | |
| Height | 90mm | |
| Standards/Approvals | RoHS, EN 60947-5-1, UL 60947-5-1 | |
| 모두 선택 | ||
|---|---|---|
브랜드 Omron | ||
Product Type Monitoring Relay | ||
Electrical Phase 1 | ||
Contact Configuration SPST | ||
Mount Type DIN Rail | ||
Minimum Current Sensed 0.1A | ||
Power Consumption 2.5VA | ||
Maximum Current Sensed 5A | ||
Current Sensitivity Overcurrent, Undercurrent | ||
Terminal Type Push-in | ||
Time Delay 250 ms | ||
IP Rating IP20 | ||
Supply AC Voltage 0V ac | ||
Minimum Operating Temperature -20°C | ||
Relay Contact Current 0.1, 5A | ||
Maximum Operating Temperature 60°C | ||
Series K8DT-AS | ||
Width 17.5mm | ||
Length 90mm | ||
Height 90mm | ||
Standards/Approvals RoHS, EN 60947-5-1, UL 60947-5-1 | ||
- COO (Country of Origin):
- CN
Omron K8DT-AS Series Monitoring Relay, 5A Maximum Current Sensed, 0.1A Minimum Current Sensed - K8DT-AS2TA
This monitoring relay detects and responds to abnormal single‑phase current conditions, providing protection against both overcurrent and undercurrent scenarios in industrial control systems. It is engineered for DIN‑rail installation and integrates with automation and electrical setups to monitor load continuity and trigger control circuits when measured current falls outside set thresholds.
Features and Benefits:
• Sensitivity range 0.1A to 5A providing precise current detection
• Single‑pole single‑throw contact offering straightforward switching action
• 250ms time delay preventing nuisance trips from short transients
• Push‑in terminals enabling Rapid tool‑free wiring connections
• Low power draw of 2.5VA reducing supply loading during operation
• IP20 enclosure suitable for standard protected electrical cabinets
• Single‑pole single‑throw contact offering straightforward switching action
• 250ms time delay preventing nuisance trips from short transients
• Push‑in terminals enabling Rapid tool‑free wiring connections
• Low power draw of 2.5VA reducing supply loading during operation
• IP20 enclosure suitable for standard protected electrical cabinets
Applications
• Suitable for motor load supervision to flag underload conditions
• Ideal for pump systems to detect dry‑run or overload situations
• Used with control panels to monitor branch circuit currents
• Can be used for conveyor systems to indicate stall or overload
• Suitable for factory automation where a Compact footprint is required
• Ideal for pump systems to detect dry‑run or overload situations
• Used with control panels to monitor branch circuit currents
• Can be used for conveyor systems to indicate stall or overload
• Suitable for factory automation where a Compact footprint is required
What mounting method does it require?
It clips onto a DIN rail for standard control‑cabinet installation and retention.
What electrical phase is monitored?
It monitors a single electrical phase for current surveillance tasks.
What Terminal type is provided for field wiring?
Push‑in terminals accept conductors for quick and secure connection without screws.
What environmental temperature range supports reliable operation?
It operates between −20°C and 60°C to cover common industrial ambient conditions.
Note
K8DT-AS allow use in either overcurrent or undercurrent mode.
K8DT-AW allow overcurrent and undercurrent monitoring simultaneously
K8DT-AW allow overcurrent and undercurrent monitoring simultaneously
Standards
EN 60947-5-1, UL 60947-5-1, IP 20 Terminals
관련된 링크들
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 2mA to 500mA, 0V ac
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 0V ac
- Omron Monitoring Relay, 3 Phase, SPST, DIN Rail, Screw
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 0.1A to 5A, 0V ac
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 0.1A to 5A, 0 V ac, 0V ac
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 10A to 200A, 0 V ac, 0V ac
- Omron Monitoring Relay, SPST, DIN Rail, Monitoring: 0 °C to 999 °C 0 V ac
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 2mA to 500mA, 0 V ac, 0V ac