Honeywell Standard Simulated Roller Lever Micro Switch, PCB Terminal Terminal, 6A, 250 V, SPDT, IP40
- RS 제품 번호:
- 205-6123
- 제조사 부품 번호:
- ZM160C20E01
- 제조업체:
- Honeywell
현재 비가용
RS는 이 제품을 더 이상 판매하지 않습니다.
- RS 제품 번호:
- 205-6123
- 제조사 부품 번호:
- ZM160C20E01
- 제조업체:
- Honeywell
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Honeywell | |
| Product Type | Micro Switch | |
| Actuator Type | Standard Simulated Roller Lever | |
| Terminal Type | PCB Terminal | |
| Contact Configuration | SPDT | |
| Housing Material | PBT | |
| IP Rating | IP40 | |
| Operating Force | 150g | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 125°C | |
| Contact AC Voltage | 250V | |
| Microswitch Type | Subminiature | |
| Depth | 10.2mm | |
| Length | 19.8mm | |
| Series | ZM1 | |
| Width | 6.4mm | |
| Standards/Approvals | CQC to GB 15092.1, cUL to UL 61058-1, UL, RoHS, REACH, ENEC to IEC 61058-1, CE, CQC | |
| Hazardous Area Certification | NO | |
| Mechanical Life | 1000000min | |
| 모두 선택 | ||
|---|---|---|
브랜드 Honeywell | ||
Product Type Micro Switch | ||
Actuator Type Standard Simulated Roller Lever | ||
Terminal Type PCB Terminal | ||
Contact Configuration SPDT | ||
Housing Material PBT | ||
IP Rating IP40 | ||
Operating Force 150g | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 125°C | ||
Contact AC Voltage 250V | ||
Microswitch Type Subminiature | ||
Depth 10.2mm | ||
Length 19.8mm | ||
Series ZM1 | ||
Width 6.4mm | ||
Standards/Approvals CQC to GB 15092.1, cUL to UL 61058-1, UL, RoHS, REACH, ENEC to IEC 61058-1, CE, CQC | ||
Hazardous Area Certification NO | ||
Mechanical Life 1000000min | ||
- COO (Country of Origin):
- CN
Honeywell ZM1 Series Micro Switch, SPCO Contact Configuration, 6A Switch Contact Current - ZM160C20E01
This micro switch provides compact, single-pole changeover switching for control and detection tasks in industrial and electronic assemblies. It is designed for PCB mounting and operates reliably across a wide temperature range, making it suitable for equipment where space is limited and consistent electrical switching is required.
Features and Benefits:
• Simulated roller lever actuator for positive mechanical engagement and consistent actuation
• SPCO contact arrangement allowing a single input to switch between circuits
• Rated switching current 6A enabling moderate-load control on PCB assemblies
• Operates from -40°C to 125°C for use across varied thermal environments
• Mechanical endurance of 400 cycles supporting repetitive actuation testing and short-run applications
• IP40 enclosure grade providing protection from solid objects in controlled environments
• SPCO contact arrangement allowing a single input to switch between circuits
• Rated switching current 6A enabling moderate-load control on PCB assemblies
• Operates from -40°C to 125°C for use across varied thermal environments
• Mechanical endurance of 400 cycles supporting repetitive actuation testing and short-run applications
• IP40 enclosure grade providing protection from solid objects in controlled environments
Applications
• Suitable for limit-switch detection in automated machinery
• Ideal for position sensing in small electromechanical assemblies
• Used for user-input switching on control PCBs in instrumentation
• Can be used for safety interlocks in Compact electrical enclosures
• Ideal for position sensing in small electromechanical assemblies
• Used for user-input switching on control PCBs in instrumentation
• Can be used for safety interlocks in Compact electrical enclosures
What Terminal style does it use for PCB integration?
It employs PCB terminals for direct through-hole mounting, simplifying board-level installation and electrical connection.
Which approvals indicate conformity to international switch standards?
The product holds multiple approvals including cUL to UL 61058-1 and ENEC to IEC 61058-1, alongside RoHS and REACH compliance for material and safety considerations.
How does the actuator type affect installation orientation?
The simulated roller lever provides a defined contact point and can be actuated from varying approach angles, aiding integration where mechanical engagement direction varies.
What environmental limitation should be considered for enclosure selection?
With an IP40 rating, the device should be placed within enclosures that limit dust ingress and prevent exposure to moisture for reliable operation.
관련된 링크들
- Honeywell Standard Simulated Roller Lever Micro Switch, Quick Connect Terminal, 6A, 250 V, SPDT, IP40
- Honeywell Standard Simulated Roller Lever Micro Switch, Solder Terminal, 100mA, 250 V, SPDT, IP40
- Honeywell Roller Lever Micro Switch, PCB Terminal Terminal, 6A, 250 V, SPDT, IP40
- Honeywell Roller Lever Micro Switch, Solder Terminal, 6A, 250 V, SPDT, IP40
- Honeywell Roller Lever Micro Switch, Quick Connect Terminal, 6A, 250 V, SPDT, IP40
- Honeywell Roller Lever Micro Switch, Solder Terminal, 10.1A, 250 V, SPDT, IP40
- Honeywell Short Lever Micro Switch, PCB Terminal Terminal, 6A, 250 V, SPDT, IP40
- Honeywell Lever Micro Switch, Solder Terminal, 6A, 250 V, SPDT, IP40