ABB SMISSLINE TP S400M Miniature Circuit Breaker, 2-Pole, 16A, Type C, 415V ac AC, 10 kA Breaking Capacity

Subtotal (1 unit)*

₩145,520.00

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2027년 1월 04일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩145,520.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
246-2570
제조사 부품 번호:
2CCS572001R0164
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Number of Poles

2

Product Type

Miniature Circuit Breaker

Current Rating

16A

Tripping Characteristics

Type C

Rated AC Voltage

415V ac

Breaking Capacity

10kA

Range

SMISSLINE TP

Series

S400M

Terminal Type

Screw

IP Rating

IP20

Height

91mm

Standards/Approvals

IEC/EN 60947-2, IEC/EN 60898-1

Width

36mm

Depth

82mm

Tripping Mechanism

Electromechanic, Thermal

Reset Actuator Type

I/O Actuator

COO (Country of Origin):
CH

ABB S400M Series Miniature Circuit Breaker, 16A Current, 415V ac Rated Voltage - 2CCS572001R0164


This miniature circuit breaker provides overcurrent protection and selective tripping for low-voltage electrical installations. It is designed for two-pole applications where coordinated thermal and electromagnetic interruption is required. The device operates within standard industrial AC systems and is suitable for distribution boards where controlled disconnection and manual reset via a clear I/O actuator are needed.

Features and Benefits:


• Tripping curve Type C limits nuisance trips from moderate inrush currents
• 10kA breaking capacity reduces risk during short-circuit events
• Electromechanical thermal magnetic trip delivers fast and delayed protection
• Screw Terminal ensures secure conductor connection under vibration
• IP20 enclosure rating allows protected indoor panel mounting

Applications


• Suitable for small commercial distribution boards
• Ideal for protecting motor feeders with moderate inrush
• Used for branch circuit protection in residential conversions
• Can be used for lighting circuits in office environments

What pole configuration does it employ?


It uses a two-pole arrangement enabling simultaneous disconnection of both live conductors.

How is the device manually reset after operation?


The unit is reset using an I/O style actuator that clearly indicates switch position.

What type of terminals are provided for conductor attachment?


Termination is via screw-type terminals designed for conventional stranded or solid conductors.

Which standards define its electrical performance?


Performance aligns with IEC/EN 60947-2 and IEC/EN 60898-1.

What is the product's physical footprint for panel planning?


The device measures 36 mm in width, 91 mm in height and 82 mm in depth.

관련된 링크들