ABB S-ARC1 S-ARC1 Miniature Circuit Breaker, 1-Pole, 10A, Type C, 240V ac AC, 6 kA Breaking Capacity
- RS 제품 번호:
- 175-9924
- 제조사 부품 번호:
- 2CSA255901R9104 S-ARC1 C10
- 제조업체:
- ABB
Subtotal (1 unit)*
₩272,342.44
재고있음
- 1 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩272,342.44 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 175-9924
- 제조사 부품 번호:
- 2CSA255901R9104 S-ARC1 C10
- 제조업체:
- ABB
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | ABB | |
| Product Type | Miniature Circuit Breaker | |
| Number of Poles | 1 | |
| Current Rating | 10A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 240V ac | |
| Mount Type | DIN Rail | |
| Breaking Capacity | 6kA | |
| Range | S-ARC1 | |
| Series | S-ARC1 | |
| Terminal Type | Cage Terminal | |
| IP Rating | IP20, IP40 | |
| Height | 85mm | |
| Depth | 69mm | |
| Width | 69mm | |
| Standards/Approvals | IEC/EN 60947-2, IEC/EN 60898-1 | |
| Reset Actuator Type | Toggle Switch | |
| Tripping Mechanism | Thermal Magnetic | |
| 모두 선택 | ||
|---|---|---|
브랜드 ABB | ||
Product Type Miniature Circuit Breaker | ||
Number of Poles 1 | ||
Current Rating 10A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 240V ac | ||
Mount Type DIN Rail | ||
Breaking Capacity 6kA | ||
Range S-ARC1 | ||
Series S-ARC1 | ||
Terminal Type Cage Terminal | ||
IP Rating IP20, IP40 | ||
Height 85mm | ||
Depth 69mm | ||
Width 69mm | ||
Standards/Approvals IEC/EN 60947-2, IEC/EN 60898-1 | ||
Reset Actuator Type Toggle Switch | ||
Tripping Mechanism Thermal Magnetic | ||
- COO (Country of Origin):
- IT
ABB S-ARC1 Series MCB, 10A Current Rating , Type C Tripping Characteristics - 2CSA255901R9104 S-ARC1 C10
This MCB is a Compact and efficient electrical safety device designed for circuit protection, featuring a 1+N pole configuration. With a current rating of 10 A, this device is suitable for use in various electrical applications. The MCB includes short circuit protection, ensuring safe operation even in critical conditions. Its DIN rail mount design enhances versatility and ease of installation, making it a dependable choice for both commercial and industrial settings.
Features & Benefits
• Type C MCB suitable for industrial applications with inrush currents
• Offers a short circuit protection device to prevent circuit damage
• 6 kA breaking capacity to handle high fault levels
• Convenient toggle switch for quick resetting
• Mounted on DIN rail for straightforward installation
• Screw Terminal circuit breaker ensures secure connections
• Offers a short circuit protection device to prevent circuit damage
• 6 kA breaking capacity to handle high fault levels
• Convenient toggle switch for quick resetting
• Mounted on DIN rail for straightforward installation
• Screw Terminal circuit breaker ensures secure connections
Applications
• Used for residential circuit protection and overload protection
• Utilised in commercial installations for lighting and equipment
• Applicable in industrial settings for machine protection
• Suitable for automation systems requiring reliable current interruption
• Utilised in commercial installations for lighting and equipment
• Applicable in industrial settings for machine protection
• Suitable for automation systems requiring reliable current interruption
What is the significance of the tripping characteristics?
The Type C tripping characteristics ensure that the circuit breaker will react appropriately to overload conditions, particularly in applications with high inrush current, allowing for increased protection of devices.
How does the DIN rail mounting benefit installation?
The DIN rail mounting provides a standardised fitting mechanism that facilitates quick and secure installation in distribution boards, saving time and effort during setup.
What does the term 1+N indicate in the product specifications?
The 1+N configuration means there is one Active pole and one NEUTRAL pole, making it suitable for single-phase systems, which simplifies wiring compared to three-phase devices.
What does the breaking capacity signify for this MCB?
The 6 kA breaking capacity indicates the maximum fault current the MCB can interrupt without damage, ensuring reliable operation in the event of a short circuit.
How can I ensure the MCB operates correctly over time?
Regular inspection of the MCB for any signs of wear or damage is advised, along with testing the reset mechanism to ensure it functions effectively when needed.
관련된 링크들
- ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker, 1-Pole, 10 A, Type C, 240 V ac AC, 10 kA Breaking Capacity
- ABB S-ARC1 S-ARC1 Miniature Circuit Breaker, 1-Pole, 20 A, Type C, 240 V ac AC, 6 kA Breaking Capacity
- ABB S-ARC1 S-ARC1 Miniature Circuit Breaker, 1-Pole, 16 A, Type C, 240 V ac AC, 6 kA Breaking Capacity
- ABB S-ARC1 S-ARC1 Miniature Circuit Breaker, 1-Pole, 6 A, Type C, 240 V ac AC, 6 kA Breaking Capacity
- ABB S-ARC1 S-ARC1 Miniature Circuit Breaker, 1-Pole, 13 A, Type C, 240 V ac AC, 6 kA Breaking Capacity
- ABB S-ARC1 S-ARC1 Miniature Circuit Breaker, 1-Pole, 10 A, Type B, 240 V ac AC, 6 kA Breaking Capacity
- ABB S-ARC1 S-ARC1 Miniature Circuit Breaker, 1-Pole, 20 A, Type B, 240 V ac AC, 6 kA Breaking Capacity
- ABB S-ARC1 S-ARC1 Miniature Circuit Breaker, 1-Pole, 16 A, Type B, 240 V ac AC, 6 kA Breaking Capacity