ABB System Pro M Compact S200 M UC Miniature Circuit Breaker, 2-Pole, 16A, Type C, 400V ac AC, 440 V dc DC, 10 kA

Subtotal (1 unit)*

₩390,740.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 추가로 2026년 11월 09일 부터 4 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩390,740.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
202-911
제조사 부품 번호:
2CDS272061R0164
제조업체:
ABB
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

ABB

Product Type

Miniature Circuit Breaker

Number of Poles

2

Current Rating

16A

Tripping Characteristics

Type C

Rated AC Voltage

400V ac

Rated DC Voltage

440V dc

Breaking Capacity

10kA

Mount Type

DIN Rail

Range

System Pro M Compact

Series

S200 M UC

Terminal Type

Screw

IP Rating

IP40, IP20

Standards/Approvals

IEC/EN 60898-2, IEC/EN 60947-2

Width

35mm

Depth

69mm

Height

88mm

Reset Actuator Type

Toggle

COO (Country of Origin):
DE

ABB S200 M UC Series Miniature Circuit Breaker, 16A Current, 2P Poles - 2CDS272061R0164


This miniature circuit breaker provides overcurrent protection for low-voltage installations. It is intended for DIN-rail mounting and offers a Compact protective device that interrupts fault currents in two-pole configurations. The unit is suitable for systems requiring both AC and DC rated switching capability and meets recognised international standards for circuit-breaker performance.

Features and Benefits:


• 10kA breaking capacity reduces prospective fault energy
• Type C tripping curve protects against moderate inrush currents
• 440V DC rated switching supports DC distribution circuits
• 400V AC operational voltage enables typical three-phase applications
• Toggle reset actuator allows quick manual reclosure

Applications


• Used with photovoltaic inverter DC protection circuits
• Ideal for motor starter circuits with moderate start-up current
• Can be used for two-pole branch-circuit protection
• Suitable for retrofit installations on standard DIN rails

What Terminal connection does it use?


It uses screw terminals for straightforward conductor termination.

How is the device mounted in an electrical enclosure?


It clips directly onto a standard DIN rail for secure installation.

What ingress protection does the enclosure provide?


The enclosure ratings are IP40 on one face and IP20 on another, indicating Basic protection levels.

What tripping behaviour should I expect with inductive loads?


The Type C characteristic permits short-duration current surges typical of inductive loads before tripping.