Honeywell GLA Series Plunger Limit Switch, 1 NO/1 NC (SPDT), IP67, Die Cast Zinc Housing, 600V ac, 6A
- RS 제품 번호:
- 311-2364
- Distrelec 제품 번호:
- 301-38-713
- 제조사 부품 번호:
- GLAB01C
- 제조업체:
- Honeywell
Subtotal (1 unit)*
₩330,700.50
재고있음
- 58 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩330,700.50 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 311-2364
- Distrelec 제품 번호:
- 301-38-713
- 제조사 부품 번호:
- GLAB01C
- 제조업체:
- Honeywell
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Honeywell | |
| Actuator Type | Plunger | |
| Product Type | Limit Switch | |
| IP Rating | IP67 | |
| Contact Configuration | 1 NO/1 NC (SPDT) | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Switching Current | 6A | |
| Series | GLA | |
| Minimum Operating Temperature | -25°C | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 600V ac | |
| Maximum Operating Temperature | 85°C | |
| Width | 42mm | |
| Standards/Approvals | UL, CSA, CE, CCC | |
| Length | 145.8mm | |
| Depth | 42mm | |
| Hazardous Area Certification | NO | |
| Operating Force | 9.5N | |
| Conduit Entry | PG13.5 | |
| Mechanical Life | 15000000Cycles | |
| 모두 선택 | ||
|---|---|---|
브랜드 Honeywell | ||
Actuator Type Plunger | ||
Product Type Limit Switch | ||
IP Rating IP67 | ||
Contact Configuration 1 NO/1 NC (SPDT) | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Switching Current 6A | ||
Series GLA | ||
Minimum Operating Temperature -25°C | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 600V ac | ||
Maximum Operating Temperature 85°C | ||
Width 42mm | ||
Standards/Approvals UL, CSA, CE, CCC | ||
Length 145.8mm | ||
Depth 42mm | ||
Hazardous Area Certification NO | ||
Operating Force 9.5N | ||
Conduit Entry PG13.5 | ||
Mechanical Life 15000000Cycles | ||
- COO (Country of Origin):
- GB

Honeywell GLA Series Limit Switch, 1NO/1NC Contact Configuration, IP67 - GLAB01C
This limit switch provides position sensing and end-of-travel detection for industrial automation and machinery control. Fitted with a plunger actuator and a snap‑action contact mechanism, it is designed for installation where robust switching performance and ingress protection are required. The enclosure is constructed from die‑cast zinc and intended for use in demanding electrical and mechanical environments.
Features and Benefits:
• IP67 rated enclosure prevents dust ingress and temporary immersion
• Snap‑action SPDT contacts deliver decisive switching performance
• Electrical switching up to 600V AC and 6 A supports high‑voltage circuits
• Mechanical endurance rated for 15 million cycles reduces maintenance frequency
• Operating temperature range from -25 to 85°C suits varied climate conditions
• PG13.5 conduit entry enables secure cable connection in wet areas
• Snap‑action SPDT contacts deliver decisive switching performance
• Electrical switching up to 600V AC and 6 A supports high‑voltage circuits
• Mechanical endurance rated for 15 million cycles reduces maintenance frequency
• Operating temperature range from -25 to 85°C suits varied climate conditions
• PG13.5 conduit entry enables secure cable connection in wet areas
Applications
• Suitable for conveyor end‑of‑travel detection in manufacturing lines
• Ideal for safety interlocks on industrial machinery panels
• Used for position feedback in automated assembly equipment
• Can be used for limit sensing in material handling systems
• Suitable for use in electrical switchgear control circuits
• Ideal for safety interlocks on industrial machinery panels
• Used for position feedback in automated assembly equipment
• Can be used for limit sensing in material handling systems
• Suitable for use in electrical switchgear control circuits
What contact arrangement does it use and how does that affect wiring?
It uses a single‑pole double‑throw contact set with one normally open and one normally closed contact, allowing both make‑and‑break signalling from a single actuator for flexible control logic.
How does the actuator type influence mechanical Interface options?
The plunger actuator provides axial actuation and is suitable where a linear striker or cam engages the switch, simplifying alignment on shafts or sliding guides.
What approvals cover its use in industrial installations?
The unit carries UL, CSA, CE and CCC recognitions, indicating it meets multiple international safety and performance standards for electrical devices.
How robust is the housing material for workshop environments?
The die‑cast zinc body offers solid mechanical protection against impacts and contributes to reliable operation in environments with physical handling and vibration.
Approvals
UL/ UL listed for Canada
Warning
GLA limit switches have not been designed as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of the products failing.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
관련된 링크들
- Honeywell GLA Series Plunger Limit Switch, DPDT, IP67, Die Cast Zinc Housing, 600 V ac, 6 A
- Honeywell GLA Series Plunger Limit Switch, 1 NO/1 NC (SPDT), IP67, Die Cast Zinc Housing, 600 V ac, 6 A
- Honeywell GLA Series Plunger Limit Switch, 1 NO/1 NC, IP67, Die Cast Zinc Housing, 600 V ac
- Honeywell GLA Series Roller Lever Limit Switch, SPDT, IP67, Die Cast Zinc Housing, 600 V ac, 6 A
- Honeywell GLA Series Rod Limit Switch, 1 NO/1 NC (SPDT), IP67, Die Cast Zinc Housing, 600 V ac, 6 A
- Honeywell GLA Series Roller Plunger Limit Switch, 2 NO/2 NC, IP67, Die Cast Zinc Housing, 600 V ac, 10 A
- Honeywell GLA Series Roller Lever Limit Switch, 1 NO/1 NC (SPDT), IP67, Die Cast Zinc Housing, 600 V ac, 6 A
- Honeywell GLA Series Coil Spring Limit Switch, 1 NO/1 NC (SPDT), IP67, Die Cast Zinc Housing, 600 V ac, 6 A