Honeywell GLA Series Plunger Limit Switch, DPDT, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 6A
- RS 제품 번호:
- 311-2465
- Distrelec 제품 번호:
- 303-44-316
- 제조사 부품 번호:
- GLAB20B
- 제조업체:
- Honeywell
Subtotal (1 unit)*
₩509,028.00
재고있음
- 추가로 2026년 5월 25일 부터 16 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩509,028.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 311-2465
- Distrelec 제품 번호:
- 303-44-316
- 제조사 부품 번호:
- GLAB20B
- 제조업체:
- Honeywell
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Plunger | |
| IP Rating | IP67 | |
| Contact Configuration | DPDT | |
| Housing Material | Die Cast Zinc Epoxy Coated | |
| Contact Type | Snap Action | |
| Switching Current | 6A | |
| Terminal Type | Screw | |
| Series | GLA | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 600V ac | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 85°C | |
| Standards/Approvals | CCC, CE, CSA, UL | |
| Length | 145.8mm | |
| Width | 42mm | |
| Depth | 42mm | |
| Hazardous Area Certification | No | |
| Mechanical Life | 15000000Cycles | |
| Operating Force | 0.33Nm | |
| Conduit Entry | Threaded conduit | |
| 모두 선택 | ||
|---|---|---|
브랜드 Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Plunger | ||
IP Rating IP67 | ||
Contact Configuration DPDT | ||
Housing Material Die Cast Zinc Epoxy Coated | ||
Contact Type Snap Action | ||
Switching Current 6A | ||
Terminal Type Screw | ||
Series GLA | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 600V ac | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 85°C | ||
Standards/Approvals CCC, CE, CSA, UL | ||
Length 145.8mm | ||
Width 42mm | ||
Depth 42mm | ||
Hazardous Area Certification No | ||
Mechanical Life 15000000Cycles | ||
Operating Force 0.33Nm | ||
Conduit Entry Threaded conduit | ||
- COO (Country of Origin):
- GB

Honeywell GLA Series Limit Switch, 145.8mm Length, IP67 - GLAB20B
This limit switch is a mechanically actuated sensor designed to detect position changes within industrial systems and provide discrete electrical switching. It is built for use where a robust plunger actuator is required to convert mechanical motion into reliable snap‑action contact changes. The device is suited to installations demanding sealed enclosures and standard safety approvals in automation, electrical and mechanical environments.
Features and Benefits:
• DPDT snap‑action contacts deliver flexible circuit control
• Rated switching up to 600V AC and 250V DC for high‑voltage tasks
• Switching current capacity of 6A supports control and signalling loads
• Mechanical life of 15 million cycles minimises replacement frequency
• Operating range from −25 °C to 85 °C enables varied ambient use
• IP67 die‑cast zinc housing provides ingress protection and robustness
• Rated switching up to 600V AC and 250V DC for high‑voltage tasks
• Switching current capacity of 6A supports control and signalling loads
• Mechanical life of 15 million cycles minimises replacement frequency
• Operating range from −25 °C to 85 °C enables varied ambient use
• IP67 die‑cast zinc housing provides ingress protection and robustness
Applications
• Suitable for conveyor end‑of‑travel detection in manufacturing lines
• Ideal for actuating safety interlocks on industrial doors
• Used with motor control systems for limit position sensing
• Can be used for machine‑tool Axis homing and overtravel protection
• Suitable for heavy‑duty packaging equipment position monitoring
• Ideal for actuating safety interlocks on industrial doors
• Used with motor control systems for limit position sensing
• Can be used for machine‑tool Axis homing and overtravel protection
• Suitable for heavy‑duty packaging equipment position monitoring
What type of actuator does it use and how does that affect contact operation?
It uses a plunger actuator which provides direct mechanical input to the snap‑action contacts, producing fast, repeatable switching for precise position detection.
How is the unit protected against dust and water ingress during washdown or outdoor use?
The enclosure meets IP67, indicating complete dust‑tight protection and temporary immersion resistance suitable for harsh environments.
Which approvals cover safety and conformity for industrial integration?
The device carries CCC, CE, CSA and UL listings, enabling compliance with a range of regional regulatory requirements.
How is electrical wiring accommodated on‑site?
A threaded conduit entry is provided to accept conduit fittings for secure cable routing and strain relief in industrial installations.
Approvals
UL/ UL listed for Canada
Warning
GLA limit switches have not been designed as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of the products failing.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
관련된 링크들
- Honeywell GLA Series Plunger Limit Switch, 1 NO/1 NC (SPDT), IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 6A
- Honeywell GLA Series Roller Lever Limit Switch, SPDT, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 6A
- Honeywell GLA Series Plunger Limit Switch, DPDT, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 6A
- Honeywell GLA Series Roller Lever Limit Switch, SPDT, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 10A
- Honeywell GLA Series Adjustable Roller Lever Limit Switch, 1 NO/1 NC (SPDT), IP67, Die Cast Zinc Epoxy Coated Housing,
- Honeywell GLA Series Plunger Limit Switch, 1 NO/1 NC, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac
- Honeywell GLA Series Rod Limit Switch, 1 NO/1 NC (SPDT), IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 6A
- Honeywell GLA Series Roller Plunger Limit Switch, 2 NO/2 NC, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 10A
