Honeywell GLD Series Roller Lever Limit Switch, SPDT, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 6A
- RS 제품 번호:
- 308-1888
- 제조사 부품 번호:
- GLDB01A1A
- 제조업체:
- Honeywell
Subtotal (1 unit)*
₩128,232.00
재고있음
- 97 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩128,232.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 308-1888
- 제조사 부품 번호:
- GLDB01A1A
- 제조업체:
- Honeywell
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Honeywell | |
| Actuator Type | Roller Lever | |
| Product Type | Limit Switch | |
| Contact Configuration | SPDT | |
| IP Rating | IP66 | |
| Housing Material | Fibreglass Reinforced Thermoplastic | |
| Contact Type | Snap Action | |
| Terminal Type | Screw | |
| Switching Current | 6A | |
| Series | GLD | |
| Switching AC Voltage | 240V ac | |
| Switching DC Voltage | 250V dc | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 85°C | |
| Length | 68.5mm | |
| Depth | 26.35mm | |
| Standards/Approvals | CCC, CE, CSA, UL | |
| Width | 30.5mm | |
| Hazardous Area Certification | No | |
| Mechanical Life | 10000000Cycles | |
| Conduit Entry | PG13.5 | |
| Operating Force | 0.12Nm | |
| 모두 선택 | ||
|---|---|---|
브랜드 Honeywell | ||
Actuator Type Roller Lever | ||
Product Type Limit Switch | ||
Contact Configuration SPDT | ||
IP Rating IP66 | ||
Housing Material Fibreglass Reinforced Thermoplastic | ||
Contact Type Snap Action | ||
Terminal Type Screw | ||
Switching Current 6A | ||
Series GLD | ||
Switching AC Voltage 240V ac | ||
Switching DC Voltage 250V dc | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 85°C | ||
Length 68.5mm | ||
Depth 26.35mm | ||
Standards/Approvals CCC, CE, CSA, UL | ||
Width 30.5mm | ||
Hazardous Area Certification No | ||
Mechanical Life 10000000Cycles | ||
Conduit Entry PG13.5 | ||
Operating Force 0.12Nm | ||

Honeywell GLD Series Limit Switch, Roller Lever Actuator, IP66 - GLDB01A1A
This limit switch provides electromechanical position sensing for industrial control systems, delivering robust performance in demanding environments. It is designed for use where a compact, sealed actuator interfacing is required and is suitable for integration into machine monitoring, safety interlocks and automated equipment.
Features and Benefits:
• SPDT snap-action contact for reliable single-pole switching
• Screw terminals enabling secure wiring connections
• Fibreglass reinforced thermoplastic housing for chemical resistance
• IP66 ingress protection for dust-tight and powerful water jets
• Mechanical endurance rated to 10 million cycles for long service life
• Operates from -40°C to 85°C for wide temperature range
• Screw terminals enabling secure wiring connections
• Fibreglass reinforced thermoplastic housing for chemical resistance
• IP66 ingress protection for dust-tight and powerful water jets
• Mechanical endurance rated to 10 million cycles for long service life
• Operates from -40°C to 85°C for wide temperature range
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for limit detection on lifting and positioning mechanisms
• Used with control panels requiring 240V AC switching at 6A
• Can be used for monitoring actuator travel in packaging equipment
• Suitable for outdoor enclosures needing sealed switching devices
• Ideal for limit detection on lifting and positioning mechanisms
• Used with control panels requiring 240V AC switching at 6A
• Can be used for monitoring actuator travel in packaging equipment
• Suitable for outdoor enclosures needing sealed switching devices
What wiring entry method does it use for conduit connection?
It accepts a PG13.5 conduit entry, allowing standard threaded conduit fittings for secure cable routing.
What switching capacities are available for electrical loads?
It switches up to 240V AC at 6A and up to 250V DC for compatible DC circuits.
How is actuation implemented and what actuator form is provided?
It uses a roller lever actuator to convert mechanical motion into switch operation for contact actuation.
What Terminal style is provided and how does it affect installation?
Termination is via screw-type terminals, permitting tool-secured connections suitable for field wiring.
Approvals
UL/ UL listed for Canada
Warning
GLC and GLD limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
관련된 링크들
- Honeywell GLD Series Adjustable Roller Lever Limit Switch, DPST, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V
- Honeywell GLD Series Roller Lever Limit Switch, SPDT, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 10A
- Honeywell GLD Series Adjustable Roller Lever Limit Switch, 1 NC/1 NO, IP66, Fibreglass Reinforced Thermoplastic Housing,
- Honeywell GLD Series Roller Lever Limit Switch, 1 NC/1 NO, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac,
- Honeywell GLD Series Plunger Limit Switch, SPDT, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 6A
- Honeywell GLD Series Plunger Limit Switch, DPST, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 10A
- Honeywell GLD Series Roller Plunger Limit Switch, DPST, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 10A
- Honeywell GLD Series Metal Roller Limit Switch, DPST, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 6A