Omron D4n Series Roller Lever Limit Switch, 1 NO/1 NC, IP67, Plastic Housing, 240V, 10A

Subtotal (1 unit)*

₩50,960.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 15 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩50,960.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
214-7535
Distrelec 제품 번호:
301-36-781
제조사 부품 번호:
D4N-2132
제조업체:
Omron
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Omron

Product Type

Limit Switch

Actuator Type

Roller Lever

Contact Configuration

1 NO/1 NC

IP Rating

IP67

Housing Material

Plastic

Contact Type

Snap Action

Switching Current

10A

Terminal Type

Screw

Series

D4n

Switching AC Voltage

240V

Minimum Operating Temperature

-30°C

Switching DC Voltage

250V

Maximum Operating Temperature

70°C

Length

72mm

Standards/Approvals

RoHS, UL, CCC, CE, CSA

Width

50mm

Depth

30mm

Hazardous Area Certification

No

Conduit Entry

G 1/2

Mechanical Life

15000000Cycles

Operating Force

6.4N

Mounting Orientation

Multi Directional

Omron D4n Series Limit Switch, 240V Switching AC Voltage, IP67 - D4N-2132


This limit switch provides a mechanical means of detecting position changes in industrial systems, converting actuator movement into an electrical signal for control or safety circuits. It is designed for environments requiring a robust switching element with Durable snap-action contacts and a roller lever actuator, suited to automation and machinery applications where discrete signalling is needed.

Features & Benefits


• IP67 ingress protection enables use in wet environments
• Snap-action contacts deliver fast, reliable switching response
• 1NO/1NC contact arrangement supports changeover logic
• 10A switching current handles substantial AC loads
• 6.4N actuation force reduces false triggers from vibration
• Mechanical life rated at 15,000,000 cycles lowers maintenance frequency

Applications


• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for machine guard interlock monitoring in assembly cells
• Used for limit sensing on automated press stroke control
• Can be used for position feedback on robotic fixtures
• Suitable for sluice gate open/close detection in water plants

What connection method does it use for wiring?


It employs screw terminals for secure conductor fixation and straightforward on-site termination.

What conduit provision is provided for cable entry?


A G1/2 conduit entry is supplied to Interface with standard industrial conduit fittings.

What temperature extremes can it endure during operation?


Operational range extends from -30°C up to +70°C for ambient environmental exposure.

How does the enclosure material affect suitability in corrosive areas?


The body is MADE from a plastic housing which offers electrical insulation and resistance to many contaminants while being lightweight.

What DC voltage can it switch for control circuit use?


It is capable of switching up to 250V DC for direct-current control or signalling requirements.