Honeywell GLE Series Coil Spring Limit Switch, DPDT, IP66, Die Cast Zinc Epoxy Coated Housing, 240V ac, 6A

Subtotal (1 unit)*

₩248,781.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 추가로 2026년 5월 25일 부터 5 개 단위 배송
  • 추가로 2026년 6월 08일 부터 25 개 단위 배송
  • 추가로 2026년 9월 28일 부터 27 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩248,781.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
186-8481
Distrelec 제품 번호:
303-44-331
제조사 부품 번호:
GLEB01E7B
제조업체:
Honeywell
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Honeywell

Actuator Type

Coil Spring

Product Type

Limit Switch

Contact Configuration

DPDT

IP Rating

IP66

Housing Material

Die Cast Zinc Epoxy Coated

Contact Type

Snap Action

Switching Current

6A

Terminal Type

Screw

Series

GLE

Minimum Operating Temperature

-40°C

Switching DC Voltage

250V dc

Switching AC Voltage

240V ac

Maximum Operating Temperature

85°C

Width

65mm

Length

189mm

Depth

30mm

Standards/Approvals

UL, CSA, CE, CCC

Hazardous Area Certification

No

Mechanical Life

10000000Cycles

Operating Force

1.3N

Conduit Entry

PG13.5

COO (Country of Origin):
GB

Honeywell GLE Series Limit Switch, 6A Switching Current, IP66 - GLEB01E7B


This limit switch provides precise mechanical position detection for industrial control and automation systems, delivering robust snap-action switching with double-pole changeover contacts for reliable circuit control in demanding environments.

Features and Benefits:


• Coil spring actuator delivers fast, repeatable actuation and reset
• IP66 enclosure protects against dust ingress and heavy water jets
• Die-cast zinc housing offers enhanced mechanical protection
• Switching capability supports 240V AC and 250V DC loads
• Mechanical endurance rated at 5 million cycles for long service life
• Low operating force of 1.3 N reduces actuator wear and energy use

Applications


• Suitable for conveyor position sensing in manufacturing lines
• Ideal for limit detection on industrial presses and shuttles
• Used with motor starters for end-of-travel detection
• Can be used for safety interlocks in assembly automation
• Used for gate or door position monitoring in outdoor installations

What contact arrangement does it provide for circuit design?


It uses a double-pole, double-throw snap-action contact set allowing two independent circuits to be switched simultaneously.

How does the device handle temperature extremes on site?


It operates across a temperature span from −25 °C to 85 °C, enabling use in both cool storage and warm process areas.

What conduit connection is available for wiring runs?


A PG13.5 threaded conduit entry is provided to simplify secure cable routing and conduit fittings.

Which approvals support integration into regulated systems?


The unit carries UL, CSA, CE and CCC approvals suitable for various international installation requirements.

Approvals

UL/ UL listed for Canada

Warning

GLE limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.

Standards

IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.

EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).

IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.

Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.