Honeywell GLE Series Plunger Limit Switch, 2 NC, IP67, Die Cast Zinc Epoxy Coated Housing, 240V ac, 6A

대량 구매 할인 기용 가능

Subtotal (1 unit)*

₩402,714.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 6 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.

수량
한팩당
1 - 5₩402,714.00
6 - 11₩390,624.00
12 +₩378,924.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
311-2336
제조사 부품 번호:
GLEB06C
제조업체:
Honeywell
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Honeywell

Actuator Type

Plunger

Product Type

Limit Switch

IP Rating

IP67

Contact Configuration

2 NC

Housing Material

Die Cast Zinc Epoxy Coated

Contact Type

Slow Action

Switching Current

6A

Terminal Type

Screw

Series

GLE

Switching AC Voltage

240V ac

Minimum Operating Temperature

-40°C

Switching DC Voltage

250V dc

Maximum Operating Temperature

85°C

Standards/Approvals

CCC, UL, CSA, CE

Width

65mm

Depth

30mm

Length

60mm

Hazardous Area Certification

No

Mechanical Life

10000000Cycles

Operating Force

0.11Nm

Conduit Entry

PG13.5

COO (Country of Origin):
GB

Honeywell GLE Series Limit Switch, 65mm Width, IP67 - GLEB06C


This limit switch is a rugged mechanical position sensor designed for industrial control and automation tasks, employing a plunger actuator to detect travel and trigger electrical contacts. It is suitable for installations requiring environmental protection and straightforward wiring, used to monitor positions, end-stops or safety interlocks in machinery and electrical panels.

Features and Benefits:


• Die-cast zinc housing provides robust mechanical protection and corrosion resistance
• IP67 ingress rating allows use in wet or dust-laden environments
• Slow-action contacts handle switching of both AC and DC loads
• Two normally-closed contacts support fail-safe circuit arrangements
• Mechanical lifespan of 15 million cycles reduces maintenance frequency
• Operating temperature range from -40°C to 85°C extends deployment options

Applications


• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for actuator limit monitoring in hydraulic and pneumatic systems
• Used with motor control panels for position feedback and interlocking
• Can be used for access door monitoring in outdoor electrical enclosures

What wiring termination does it use and how is cable entry handled?


Terminals are screw type for secure conductor connection and the enclosure accepts a PG13.5 conduit entry for standard gland fittings.

What electrical loads can it switch?


It is capable of switching AC loads at 240V and DC up to 250V with a continuous current rating of 6 A.

How Compact is the unit for tight installations?


The design has a Compact footprint of 60 x 65 x 30mm suitable for confined mounting spaces.

What actuator torque or force characteristics are relevant for mounting?


The actuator requires an operating torque of 0.11 N·m, informing lever and actuator interfacing for correct actuation timing.

Approvals

UL/ UL listed for Canada

Warning

GLE limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.

Standards

IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.

EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).

IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.

Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.