사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Adjustable Roller Lever | |
| Contact Configuration | DPDT | |
| IP Rating | IP67 | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Terminal Type | M20 | |
| Switching Current | 6A | |
| Series | GLA | |
| Switching AC Voltage | 600V ac | |
| Switching DC Voltage | 250V dc | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 85°C | |
| Width | 42mm | |
| Standards/Approvals | CCC, CE, CSA, UL | |
| Length | 145.8mm | |
| Depth | 42mm | |
| Hazardous Area Certification | NO | |
| Mounting Orientation | Side | |
| Mechanical Life | 15000000Cycles | |
| Conduit Entry | 20 mm | |
| Operating Force | 0.33Nm | |
| 모두 선택 | ||
|---|---|---|
브랜드 Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Adjustable Roller Lever | ||
Contact Configuration DPDT | ||
IP Rating IP67 | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Terminal Type M20 | ||
Switching Current 6A | ||
Series GLA | ||
Switching AC Voltage 600V ac | ||
Switching DC Voltage 250V dc | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 85°C | ||
Width 42mm | ||
Standards/Approvals CCC, CE, CSA, UL | ||
Length 145.8mm | ||
Depth 42mm | ||
Hazardous Area Certification NO | ||
Mounting Orientation Side | ||
Mechanical Life 15000000Cycles | ||
Conduit Entry 20 mm | ||
Operating Force 0.33Nm | ||
- COO (Country of Origin):
- GB



Honeywell GLA Series Limit Switch, 20mm Conduit Entry, 1 NC/1 NO Contact Configuration - GLAC01A2B
This limit switch provides mechanical position sensing for industrial control systems, delivering snap-action contact switching in demanding environments. It is intended for side-mounted installations where a compact, watertight actuator is required and supports both AC and DC switching duties for automation, electrical and mechanical equipment.
Features and Benefits:
• Snap-action contacts provide Rapid state change and clear signalling
• 1NC and 1NO contact arrangement offers flexible circuit options
• IP67 ingress protection enables use in wet or dusty locations
• Electrostatic epoxy-coated zinc housing resists corrosion in harsh sites
• Rated for 600V AC and 6A to handle common control voltages
• High mechanical life of 15,000,000 operations reduces replacement frequency
• 1NC and 1NO contact arrangement offers flexible circuit options
• IP67 ingress protection enables use in wet or dusty locations
• Electrostatic epoxy-coated zinc housing resists corrosion in harsh sites
• Rated for 600V AC and 6A to handle common control voltages
• High mechanical life of 15,000,000 operations reduces replacement frequency
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for gate and valve position feedback in process plants
• Used with packaging machinery for stroke-limit monitoring
• Can be used for safety interlocks on machine guards
• Suitable for actuator position sensing in electrical switchgear
• Ideal for gate and valve position feedback in process plants
• Used with packaging machinery for stroke-limit monitoring
• Can be used for safety interlocks on machine guards
• Suitable for actuator position sensing in electrical switchgear
What actuator type does it use and how does that affect mounting?
It employs an adjustable roller lever actuator that allows fine alignment of the contact point and is designed for side-oriented mounting to suit linear travel mechanisms.
How is electrical connection provided for conduit-based wiring?
Wiring is fed through an M20 conduit entry to maintain enclosure integrity and permit standard industrial conduit fittings.
What operating temperatures can it tolerate during continuous service?
The device is specified to function between -25°C and 85°C, supporting applications exposed to low and elevated ambient temperatures.
What standards and approvals cover its safe adoption in installations?
It conforms to several recognised standards including CE, UL, CSA and CCC to align with international regulatory expectations.
How does the design support repetitive switching in high-cycle applications?
The snap-action contact mechanism combined with a robust housing contributes to the listed mechanical endurance for prolonged duty cycles.
Approvals
UL/ UL listed for Canada
Warning
GLA limit switches have not been designed as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of the products failing.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
관련된 링크들
- Honeywell GLA Series Adjustable Roller Lever Limit Switch, 1 NO/1 NC, IP67, Die Cast Zinc Housing
- Honeywell GLA Series Adjustable Roller Lever Limit Switch, SPDT, IP67, Die Cast Zinc Housing, 600 V ac, 6 A
- Honeywell GLA Series Roller Lever Limit Switch, DPDT, IP67, Die Cast Zinc Housing, 600 V ac, 6 A
- Honeywell GLA Series Adjustable Roller Lever Limit Switch, 2 NC, IP67, Die Cast Zinc Housing, 600 V ac, 6 A
- Honeywell GLA Series Plunger Limit Switch, DPDT, IP67, Die Cast Zinc Housing, 600 V ac, 6 A
- Honeywell GLA Series Roller Lever Limit Switch, 1 NO/1 NC, IP67, Die Cast Zinc Housing, 600 V ac
- Honeywell GLA Series Adjustable Roller Lever Limit Switch, 2 NO/2 NC, IP67, Die Cast Zinc Housing, 600 V ac, 10 A
- Honeywell GLA Series Adjustable Roller Lever Limit Switch, 1 NO/1 NC, IP67, Die Cast Zinc Housing, 600 V ac, 10 A