Honeywell GLA Series Adjustable Roller Lever Limit Switch, 2 NC, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 6A
- RS 제품 번호:
- 311-2229
- Distrelec 제품 번호:
- 301-38-720
- 제조사 부품 번호:
- GLAC06A2B
- 제조업체:
- Honeywell
Subtotal (1 unit)*
₩529,210.50
재고있음
- 3 개 단위 배송 준비 완료
- 추가로 2026년 6월 01일 부터 25 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩529,210.50 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 311-2229
- Distrelec 제품 번호:
- 301-38-720
- 제조사 부품 번호:
- GLAC06A2B
- 제조업체:
- Honeywell
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Honeywell | |
| Actuator Type | Adjustable Roller Lever | |
| Product Type | Limit Switch | |
| Contact Configuration | 2 NC | |
| IP Rating | IP67 | |
| Housing Material | Die Cast Zinc Epoxy Coated | |
| Contact Type | Slow Action | |
| Terminal Type | M20 | |
| Switching Current | 6A | |
| Series | GLA | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 600V ac | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 85°C | |
| Depth | 42mm | |
| Length | 145.8mm | |
| Standards/Approvals | CSA, CCC, CE, UL | |
| Width | 42mm | |
| Hazardous Area Certification | No | |
| Operating Force | 0.33Nm | |
| Mechanical Life | 15000000Cycles | |
| Conduit Entry | 20 mm | |
| 모두 선택 | ||
|---|---|---|
브랜드 Honeywell | ||
Actuator Type Adjustable Roller Lever | ||
Product Type Limit Switch | ||
Contact Configuration 2 NC | ||
IP Rating IP67 | ||
Housing Material Die Cast Zinc Epoxy Coated | ||
Contact Type Slow Action | ||
Terminal Type M20 | ||
Switching Current 6A | ||
Series GLA | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 600V ac | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 85°C | ||
Depth 42mm | ||
Length 145.8mm | ||
Standards/Approvals CSA, CCC, CE, UL | ||
Width 42mm | ||
Hazardous Area Certification No | ||
Operating Force 0.33Nm | ||
Mechanical Life 15000000Cycles | ||
Conduit Entry 20 mm | ||
- COO (Country of Origin):
- GB

Honeywell GLA Series Limit Switch, 20mm Conduit Entry, Adjustable Roller Lever Actuator - GLAC06A2B
This limit switch is a rugged mechanical device designed to detect and control position in industrial systems. It employs an adjustable roller lever actuator to provide repeatable end-of-travel signalling for automated machinery and safety interlocks. The unit is built for demanding environments with a sealed housing and standard electrical switching ratings suitable for both AC and DC control circuits.
Features and Benefits:
• Die-cast zinc housing provides robust protection against impact
• IP67 ingress rating allows operation in wet or dusty locations
• 2 NC slow-action contacts support stable switching behaviour
• Rated for 600V AC and 250V DC to handle common control voltages
• Mechanical life of 15 000 000 cycles minimises replacement frequency
• Operating range from −25 °C to 85 °C enables high-temperature deployment
• IP67 ingress rating allows operation in wet or dusty locations
• 2 NC slow-action contacts support stable switching behaviour
• Rated for 600V AC and 250V DC to handle common control voltages
• Mechanical life of 15 000 000 cycles minimises replacement frequency
• Operating range from −25 °C to 85 °C enables high-temperature deployment
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for limit sensing on industrial packaging machinery
• Used with motor starters for position-based isolation in plants
• Can be used for gate and door position monitoring in outdoor sites
• Used for actuation feedback in assembly automation systems
• Ideal for limit sensing on industrial packaging machinery
• Used with motor starters for position-based isolation in plants
• Can be used for gate and door position monitoring in outdoor sites
• Used for actuation feedback in assembly automation systems
What conduit entry does it accept and how does that affect installation?
It accepts an M20 conduit entry allowing standard metric gland fittings and straightforward cable routing in control panels.
How does the actuator type influence sensor alignment?
The adjustable roller lever permits fine tuning of actuator position for precise trip points and accommodates varying cam or follower geometries.
What performance should be expected from the switching contacts under load?
The slow-action contact pair is rated for 6A switching current, suitable for direct control of many relays and contactors within its voltage limits.
How does the devices mechanical specification impact lifecycle planning?
With a specified mechanical life of 15 000 000 cycles, it supports long-term operation in high-cycle applications, reducing maintenance intervals.
Approvals
UL/ UL listed for Canada
Warning
GLA limit switches have not been designed as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of the products failing.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
Contents
GLS DIN
관련된 링크들
- Honeywell GLA Series Plunger Limit Switch, DPDT, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 6A
- Honeywell GLA Series Plunger Limit Switch, 1 NO/1 NC, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac
- Honeywell GLA Series Roller Lever Limit Switch, DPDT, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 6A
- Honeywell GLA Series Adjustable Roller Lever Limit Switch, 1 NO/1 NC (SPDT), IP67, Die Cast Zinc Epoxy Coated Housing,
- Honeywell GLA Series Adjustable Roller Lever Limit Switch, 2 NO/2 NC, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac,
- Honeywell GLA Series Adjustable Roller Lever Limit Switch, 1 NO/1 NC, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac,
- Honeywell GLA Series Roller Lever Limit Switch, SPDT, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 6A
- Honeywell GLA Series Roller Lever Limit Switch, SPDT, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 10A