SICK C40S Series Light Curtain Sender, 30 mm Resolution

Subtotal (1 unit)*

₩3,223,420.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 11월 23일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩3,223,420.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-0975
제조사 부품 번호:
C40S-0703CA010
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Light Curtain

Series

C40S

Beam Resolution

30mm

Component Type

Sender

Safety Type

Type 4

Standards/Approvals

ACMA, CE, cUL, EC-Type-Examination, GB, GB/T, IEC, Moroccan, OSHA, RoHS, UKCA, cULus

Protective Height

750mm

Maximum Supply Voltage

24V

Maximum Scanning Distance

10m

Width

40mm

Height

879mm

Length

48mm

COO (Country of Origin):
DE

SICK C40S Series Light Curtain, 750mm Protective Height, 30mm beam resolution - C40S-0703CA010


This light curtain is a Type 4 safety sensor intended for normal industrial environments to protect personnel and machinery. It operates as a sender component within a safety system, using optical synchronisation to establish a protective field and is designed for integration with safety relays and device communication protocols. The unit runs from a 24V supply and is supplied with electrical and environmental protection suitable for factory conditions.

Features and Benefits:


• 10m maximum scanning distance provides extended coverage for larger installations
• 30mm beam resolution enables detection of small intrusions
• SIL3 safety integrity level supports high-risk machine guarding
• Category 4 classification ensures fault-tolerant safety operation
• IP65 enclosure rating permits use in dusty and damp areas

Applications


• Suitable for safeguarding automated assembly lines
• Ideal for access protection on packaging machinery
• Used with safety relays for restart interlock implementations
• Can be used for perimeter protection in robotics cells
• Used for integration where optical synchronisation is required

What supply voltage is required for operation?


It requires a 24V DC supply within a 19.2V to 28.8V operating window.

How does the device report a safe state during faults?


In the event of a fault, at least one OSSD output is driven to the OFF state.

What environmental limits apply to storage and operation?


It operates between 0°C and +55°C and may be stored between -25°C and +70°C.

Which approvals cover electrical and regulatory conformity?


It holds CE, UKCA, cUL, ULus, GB/GB·T, ACMA and other regional declarations.

관련된 링크들