SICK LFP0450 Series TDR Level Sensor Level Sensor, PNP Output, Stainless Steel 303 Body

Subtotal (1 unit)*

₩1,978,681.20

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 5월 05일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩1,978,681.20

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-2052
제조사 부품 번호:
LFP0450-G1NMB
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Device Type

TDR Level Sensor

Switch Output

PNP

Body Material

Stainless Steel 303

Cable Length

450mm

Minimum Operating Temperature

-20°C

Communication Protocol

IO-LINK

Maximum Operating Temperature

+150°C

Maximum DC Voltage

30V

Thread Size

G3/4

Maximum Current

100 mA

Maximum Pressure

16bar

Process Connection

G3/4

Series

LFP0450

Interface

IO-Link

Standards Met

CE, cULus

COO (Country of Origin):
DE

Overview


The LFP Inox is a hygienic level sensor for liquids using TDR technology – a process for determining the time of flight of electromagnetic waves. The time difference between the sent pulse and the reflected pulse is used to generate a level signal, both as a continuous value (analogue output) and a freely positionable switching point (switching output). The use of FDA-compliant materials in an EHEDG-certified design means that the LFP Inox can be relied upon for optimum and unrestricted cleaning, even in applications with the most stringent hygiene requirements. Its modular connection system allows simple and flexible installation in any application.

Thanks to high temperature and pressure resistance, unrestricted use is possible under CIP and SIP conditions. This impressive profile is topped off with communication capability via IO-Link to the superordinate control units.

At a glance


Level measurement in hygienic applications

Rod probe can be cut to length manually up to 4,000 mm long with Ra ≤ 0.8 μm (optionally with Ra ≤ 0.4 μm)

Process temperature up to 180 °C, process pressure up to 16 bar

CIP/SIP-resistant

High enclosure rating: IP 67 and IP 69, autoclavable

Interchangeable hygienic process connections

3 in 1: combines display, analogue output, and binary output

Remote amplifier with process connection

IO-Link 1.1

Your Benefit


Rugged design increases service life

High flexibility – rod probe can be cut to length and connection concept is interchangeable

Cost savings as a result of multiple output signals: one system for both point level and continuous level measurement

Maintenance-free and easy to commission without calibration, saving time and money

Remote display of measured values and saves space

Applications


Fields of applications

Level monitoring in buffer tanks of filling systems and filling machines

Level monitoring in rinsing systems

Level monitoring in CIP systems

Level measurement in mixing systems in the cosmetics and pharmaceuticals industry

Level mon