Endress+Hauser FMU30 Series Ultrasonic Level Sensor Level Sensor, Threaded Mount, ATEX-Rated, Ethylene Propylene Diene
- RS 제품 번호:
- 256-6160
- Distrelec 제품 번호:
- 303-51-198
- 제조사 부품 번호:
- FMU30-AAHEAAGGF
- 제조업체:
- Endress+Hauser
Subtotal (1 unit)*
₩1,873,260.00
재고있음
- 7 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩1,873,260.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 256-6160
- Distrelec 제품 번호:
- 303-51-198
- 제조사 부품 번호:
- FMU30-AAHEAAGGF
- 제조업체:
- Endress+Hauser
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Endress+Hauser | |
| Product Type | Level Sensor | |
| Device Type | Ultrasonic Level Sensor | |
| Mount Type | Threaded Mount | |
| Housing Material | Polypropylene | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 60°C | |
| Maximum DC Voltage | 30V dc | |
| Maximum Pressure | 3bar | |
| Gasket Material | Ethylene Propylene Diene Monomer | |
| Standards/Approvals | CE mark | |
| Series | FMU30 | |
| Hazardous Area Certification | ATEX | |
| 모두 선택 | ||
|---|---|---|
브랜드 Endress+Hauser | ||
Product Type Level Sensor | ||
Device Type Ultrasonic Level Sensor | ||
Mount Type Threaded Mount | ||
Housing Material Polypropylene | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 60°C | ||
Maximum DC Voltage 30V dc | ||
Maximum Pressure 3bar | ||
Gasket Material Ethylene Propylene Diene Monomer | ||
Standards/Approvals CE mark | ||
Series FMU30 | ||
Hazardous Area Certification ATEX | ||
- COO (Country of Origin):
- DE
Endress+Hauser FMU30 Series Level Sensor, 60°C Maximum Operating Temperature, 3 Bar Maximum Pressure - FMU30-AAHEAAGGF
This level sensor is an ultrasonic device designed to monitor fluid levels in industrial processes where a threaded mount is required. It operates across a wide ambient temperature range and is suitable for installations requiring hazardous-area certification and low-voltage signalling. The unit is housed in a durable polymer enclosure with a threaded G 1/2 connection and uses an elastomeric seal to maintain process integrity.
Features and Benefits:
• Operates reliably from -20°C to 60°C for varied ambient conditions
• Withstands up to 10 bar? No, correct: tolerates 3 bar process pressure for pressurised vessels
• Accepts up to 30V DC enabling low-voltage installations
• Draws 22 mA for minimal power consumption during continuous monitoring
• Polybutylene terephthalate housing for chemical-resistant external protection
• EPDM gasket ensures resilient sealing against common process media
• Withstands up to 10 bar? No, correct: tolerates 3 bar process pressure for pressurised vessels
• Accepts up to 30V DC enabling low-voltage installations
• Draws 22 mA for minimal power consumption during continuous monitoring
• Polybutylene terephthalate housing for chemical-resistant external protection
• EPDM gasket ensures resilient sealing against common process media
Applications
• Suitable for level control in small pressurised tanks and vessels
• Ideal for integration into low-voltage control loops in factory automation
• Used for monitoring liquids in areas requiring ATEX hazardous-area compliance
• Can be used with threaded process fittings where G 1/2 connections are standard
• Suitable for retrofit replacement of ultrasonic transmitters with threaded mounts
• Ideal for integration into low-voltage control loops in factory automation
• Used for monitoring liquids in areas requiring ATEX hazardous-area compliance
• Can be used with threaded process fittings where G 1/2 connections are standard
• Suitable for retrofit replacement of ultrasonic transmitters with threaded mounts
What certifications enable use in potentially explosive atmospheres?
It carries ATEX hazardous-area certification permitting installation in zoned areas where the certification criteria are met.
How is the sensor sealed at the process interface?
A gasket made from ethylene propylene diene monomer provides the seal between the sensor and the mating thread to limit ingress and maintain process separation.
What electrical limits must be observed when connecting the device?
The transmitter must not be supplied above 35V AC or 30V DC and its operating current is typically 22 mA, so wiring and power sources should match these ratings.
Which mounting hardware is required for installation?
A compatible G 1/2 threaded port is needed for the threaded mount
ensure correct torque and sealing practice for the specified gasket material.
관련된 링크들
- Endress+Hauser FMU30 Series Ultrasonic Ultrasonic Level Sensor, Wall Mount, ATEX, IECEx-Rated, Housing Polybutylene
- Endress+Hauser Prosonic T FMU30 Series Ultrasonic Level Sensor, Wall Mount, ATEX-Rated, Housing Polybutylene
- Endress+Hauser Prosonic M FMU41 Series Ultrasonic Level Measurement Ultrasonic Level Sensor, Flange, ATEX-Rated, Housing
- Endress+Hauser Prosonic M FMU40 Series Ultrasonic Level Measurement Ultrasonic Level Sensor, Flange, ATEX-Rated, Housing
- Endress+Hauser Prosonic M FMU42 Series Ultrasonic Level Measurement Ultrasonic Level Sensor, Flange, ATEX-Rated, Housing
- Endress+Hauser Prosonic T FMU30 Series Ultrasonic Level Sensor, Wall Mount, IECEx, ATEX-Rated, Housing Polybutylene
- Endress+Hauser Prosonic T FMU30 Series Ultrasonic Level Sensor, Wall Mount, ATEX, IECEx-Rated, Housing Polybutylene
- Endress+Hauser FMI21 Series Capacitive Level Sensor Level Sensor, Threaded Mount, Ethylene Propylene Diene Monomer,
