- RS 제품 번호:
- 330-7809
- 제조사 부품 번호:
- 207183 T3-3-8212/I2
- 제조업체:
- Eaton
- RS 제품 번호:
- 330-7809
- 제조사 부품 번호:
- 207183 T3-3-8212/I2
- 제조업체:
- Eaton
제정법과 컴플라이언스
- COO (Country of Origin):
- GB
제품 세부 사항
Eaton Non-Fused Switch Disconnectors - T3 Series Rotary Switches
The T3 series of switch disconnectors from Eaton are compact and robust. Rotary Cam Switches can be used for many switching and control applications, for example as ON-OFF, main, main/control, or instrument switches. The device consists of a hand actuator, the switch unit and the mounting accessories. This range of isolator switches is also suitable for use in applications where there is a need to manually power down and disconnect electrical equipment for servicing and maintenance by cutting the power supply to isolated parts of the circuit. These disconnect switches can also be used as safety switches.
With an IP65 degree of protection, the devices are suited to hard-wearing industrial environments with a rated uninterrupted current of up to 32 A. Available in four different mounting options (surface mounting, flush mounting, rear mounting, and service distribution board mounting). These switches can be selected and configured in a multitude of contact sequences.
With an IP65 degree of protection, the devices are suited to hard-wearing industrial environments with a rated uninterrupted current of up to 32 A. Available in four different mounting options (surface mounting, flush mounting, rear mounting, and service distribution board mounting). These switches can be selected and configured in a multitude of contact sequences.
Performs local isolation, manual override & safety switch functions
T3 Series fit a standard front plate of 45 x 45 mm
For spare rotary thumb stick (black) see stock no. 176-9759
T3 Series fit a standard front plate of 45 x 45 mm
For spare rotary thumb stick (black) see stock no. 176-9759
What is the difference between a fused switch disconnector and a non-fused switch disconnector?
Unlike fused switch disconnectors, a non-fuse isolator switch does not use a fuse to break or put a circuit into isolation, they instead use a rotary switch or knife-blade disconnect to isolate and de-energise a circuit. Commonly used in industrial automation and control settings.
Note
Eaton formerly known as Moeller
사양
속성 | 값 |
---|---|
Number of Poles | 3P |
IP Rating | IP65 |
Power Rating | 22kW |
Voltage Rating | 240 V dc, 690V ac |
Electrical Phase | 3 |
Handle Colour | Black |
Series | Eaton Moeller |
Normal State Configuration | 3NO/3NC |
Switch Rating | 6000V ac |
Length | 180mm |
Width | 100mm |
Depth | 135mm |
Maximum Operating Temperature | +40°C |
Minimum Operating Temperature | -25°C |
Terminal Type | Screw |