RS Better World
SICK FTMG Series Gas Flow Meter for Compressed Air, 14.7L/min Min, 4417L/min Max
- RS 제품 번호:
- 210-1291
- 제조사 부품 번호:
- FTMG-ISD25AXO
- 제조업체:
- SICK
Subtotal (1 unit)*
₩8,078,400.00
제조사가 재고 비축중
- 2026년 9월 25일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩8,078,400.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
Our Better World range features products that make it easy for you to make a greener product choice you can trust.
Learn more about RS Better World products
- RS 제품 번호:
- 210-1291
- 제조사 부품 번호:
- FTMG-ISD25AXO
- 제조업체:
- SICK
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | SICK | |
| Product Type | Flow Meter | |
| Media Monitored | Compressed Air | |
| Device Type | Gas | |
| Minimum Flow Rate | 14.7L/min | |
| Maximum Flow Rate | 4417L/min | |
| Housing Material | Stainless Steel | |
| Connection Type | G1 Male | |
| Maximum Pressure | 16bar | |
| Minimum Media Temperature | -20°C | |
| Maximum Supply Voltage | 30V dc | |
| IP Rating | IP67, IP65 | |
| Maximum Media Temperature | 60°C | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | CE | |
| Series | FTMG | |
| Better World Product | Yes | |
| Better World Claim | Saves Energy | |
| 모두 선택 | ||
|---|---|---|
브랜드 SICK | ||
Product Type Flow Meter | ||
Media Monitored Compressed Air | ||
Device Type Gas | ||
Minimum Flow Rate 14.7L/min | ||
Maximum Flow Rate 4417L/min | ||
Housing Material Stainless Steel | ||
Connection Type G1 Male | ||
Maximum Pressure 16bar | ||
Minimum Media Temperature -20°C | ||
Maximum Supply Voltage 30V dc | ||
IP Rating IP67, IP65 | ||
Maximum Media Temperature 60°C | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals CE | ||
Series FTMG | ||
Better World Product Yes | ||
Better World Claim Saves Energy | ||
- COO (Country of Origin):
- DE
SICK FTMG Series Flow Switch, 14.7 L/min Minimum Flow Rate, 4417 L/min Maximum Flow Rate - FTMG-ISD25AXO
This flow switch, designed for gas monitoring, effectively manages the flow of various gases including air, argon, nitrogen, and carbon dioxide. With a pipe diameter capacity of 25mm and a robust stainless steel construction, it is suitable for high-pressure environments, handling up to 16 bar. The device operates within a supply voltage range of 17 to 30 V DC and maintains performance across a temperature range of -20°C to +60°C.
Features & Benefits
• Monitors airflow with a minimum flow rate of 14.7 l/min
• Supports high performance with a maximum flow rate of 4417 l/min
• Constructed from stainless steel for durability in demanding conditions
• Operates efficiently at a current rating of 12W at 24V DC
• Ideal for effective flow rate monitoring in industrial settings
• Supports high performance with a maximum flow rate of 4417 l/min
• Constructed from stainless steel for durability in demanding conditions
• Operates efficiently at a current rating of 12W at 24V DC
• Ideal for effective flow rate monitoring in industrial settings
Applications
• Used with gas pipelines for industrial and commercial processes
• Applicable in HVAC systems to maintain airflow parameters
• Utilised in laboratories for precise gas management tasks
• Suitable for automation where flow regulation is critical
• Effective in environments requiring robust gas monitoring solutions
• Applicable in HVAC systems to maintain airflow parameters
• Utilised in laboratories for precise gas management tasks
• Suitable for automation where flow regulation is critical
• Effective in environments requiring robust gas monitoring solutions
What is the maximum pressure this device can tolerate when monitoring gas flow?
It can withstand pressures up to 16 bar, making it suitable for high-pressure applications.
What types of gases can be monitored with this switch?
This device effectively monitors various gases including air, argon, nitrogen, and carbon dioxide, providing versatility for different applications.
How do the temperature specifications impact its performance?
The flow switch operates across a temperature range of -20°C to +60°C, allowing it to function reliably in varying environmental conditions.
What is the significance of the G1 male connection type?
The G1 male connection facilitates secure and straightforward installation, ensuring effective integration into existing systems.
관련된 링크들
- SICK FTMG Series Gas Flow Meter, 14.7L/min Min, 4417L/min Max
- SICK FTMG Series Gas Flow Meter, 9.4L/min Min, 2824L/min Max
- SICK FTMG Series Gas Flow Meter, 5.3L/min Min, 1590L/min Max
- SICK FTMG Series Flow Sensor Flow Sensor, 37.7L/min Min, 11309.7L/min Max
- SICK FTMG Series Flow Sensor Flow Sensor, 58.9L/min Min, 11780.9L/min Max
- SICK FTMG Series Flow Sensor Flow Sensor, 37.7L/min Min, 7539.8L/min Max
- Sensirion SFM3013-300-CLM Series Digital Flow Meter Flow Sensor for Gas, 30L/min Min, 300L/min Max
- SICK FTMG Series Fluid Sensor Flow Sensor for Compressed Air, Helium, 58.9L/min Min, 780.9L/min Max