Sensata / Cynergy3 SSV66A-34N Series Vertical Float Switch, 1 m Cable, NO/NC, 300 V ac Max, 300 V dc Max
- RS 제품 번호:
- 756-4148
- 제조사 부품 번호:
- SSV66A24E34NP
- 제조업체:
- Sensata / Cynergy3
본 이미지는 참조용이오니 재확인이 필요하시면 문의해주세요.
대량 구매 할인 기용 가능
Subtotal (1 unit)*
₩297,096.40
마지막 RS 재고
- 최종적인 1 개 unit(s)이 배송 준비 됨
수량 | 한팩당 |
|---|---|
| 1 - 5 | ₩297,096.40 |
| 6 + | ₩279,800.40 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 756-4148
- 제조사 부품 번호:
- SSV66A24E34NP
- 제조업체:
- Sensata / Cynergy3
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Sensata / Cynergy3 | |
| Product Type | Float Switch | |
| Mount Type | Vertical | |
| Switch Output | NO/NC | |
| Housing Material | 316L Stainless Steel | |
| Cable Length | 1m | |
| Maximum Operating Temperature | 120°C | |
| Maximum AC Voltage | 300V | |
| Maximum DC Voltage | 300V | |
| Maximum Current | 500mA | |
| Maximum Pressure | 30bar | |
| Standards/Approvals | No | |
| Hazardous Area Certification | No | |
| Series | SSV66A-34N | |
| 모두 선택 | ||
|---|---|---|
브랜드 Sensata / Cynergy3 | ||
Product Type Float Switch | ||
Mount Type Vertical | ||
Switch Output NO/NC | ||
Housing Material 316L Stainless Steel | ||
Cable Length 1m | ||
Maximum Operating Temperature 120°C | ||
Maximum AC Voltage 300V | ||
Maximum DC Voltage 300V | ||
Maximum Current 500mA | ||
Maximum Pressure 30bar | ||
Standards/Approvals No | ||
Hazardous Area Certification No | ||
Series SSV66A-34N | ||
- COO (Country of Origin):
- CN
SSV66 Series Stainless Steel Float Switch
The SSV66 series of float switches provide high, low or high and low level monitoring for 45 gallon drums, these float switches do not require access to the inside of the drum as they can be fitted from the outside of the drum through the 3/4" NPT bung hole.
Suitable for a 45 Gallon drum hi/lo level switching
External mount via 3/4" NPT
N/O or N/C switching action
Fits standard 3/4" NPT bung holes
Flying lead or 4 pin M12 connection
Warning
The Cable entry point must NOT under any circumstances be submerged.
On the Horizontal switches they must be fitted through the wall of a tank so that the cable is on the outside.
On the vertical type the mounting thread and cable entry must be above the highest level of the liquid.
On the Horizontal switches they must be fitted through the wall of a tank so that the cable is on the outside.
On the vertical type the mounting thread and cable entry must be above the highest level of the liquid.
관련된 링크들
- Sensata Cynergy3 SSV66A-34N Series Vertical Stainless Steel Float Switch, Float, NO/NC
- Sensata Cynergy3 SSV66A-34N Series Vertical Stainless Steel Float Switch, Float, 1m Cable, NO/NC
- Sensata Cynergy3 SSV66A-34N Series Vertical Stainless Steel Float Switch, Float, 1m Cable, NO/NC, 300V ac Max, 300V dc
- Sensata Cynergy3 SSV66-SM16 Series Vertical Stainless Steel Float Switch, Float, 1m Cable, NO/NC
- Sensata Cynergy3 SSV66A-1G Series Vertical Stainless Steel Float Switch, Float, NO/NC, 300V ac Max, 300V dc Max
- Sensata Cynergy3 SSV66-SM16 Series Vertical Stainless Steel Float Switch, Float, 1m Cable, NO/NC, 300V ac Max, 300V dc
- Sensata Cynergy3 Horizontal Stainless Steel Float Switch, Float, 1m Cable, NO/NC
- Sensata Cynergy3 SSH66XE Series Horizontal Stainless Steel Float Switch, Float, 1m Cable, NO/NC, 300V ac Max, 300V dc