HellermannTyton Connectivity CA076 Cat6 Cable, Unshielded, 305 m, Violet Polyethylene
- RS 제품 번호:
- 327-338
- 제조사 부품 번호:
- CA076 DCA
- 제조업체:
- HellermannTyton Connectivity
Subtotal (1 reel of 305 metres)*
₩350,640.00
재고있음
- 12 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
릴당 | 릴당 | 미터당* |
|---|---|---|
| 1 + | ₩350,640.00 | ₩1,150.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 327-338
- 제조사 부품 번호:
- CA076 DCA
- 제조업체:
- HellermannTyton Connectivity
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | HellermannTyton Connectivity | |
| Series | CA076 | |
| Product Type | Cat6 Cable | |
| Cable Length | 305m | |
| LAN Category | Cat6 | |
| Terminated/Unterminated | Unterminated | |
| Shield Type | Unshielded | |
| Conductor Type | Twisted Pair | |
| Jacket Material | Polyethylene | |
| Jacket Colour | Violet | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 60°C | |
| Fire Behaviour | LSOH | |
| Standards/Approvals | IEC 61156-5, ISO 11801:2002, C& UKCA, BS EN 50288-10-1, BS EN 50173, ANSI/TIA/EIA 568-C.2 | |
| Cable CSA | 23AWG | |
| Voltage | 230V | |
| Conductor Material | Copper | |
| Number of Cores | 2 | |
| Outside Diameter | 6mm | |
| 모두 선택 | ||
|---|---|---|
브랜드 HellermannTyton Connectivity | ||
Series CA076 | ||
Product Type Cat6 Cable | ||
Cable Length 305m | ||
LAN Category Cat6 | ||
Terminated/Unterminated Unterminated | ||
Shield Type Unshielded | ||
Conductor Type Twisted Pair | ||
Jacket Material Polyethylene | ||
Jacket Colour Violet | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 60°C | ||
Fire Behaviour LSOH | ||
Standards/Approvals IEC 61156-5, ISO 11801:2002, C& UKCA, BS EN 50288-10-1, BS EN 50173, ANSI/TIA/EIA 568-C.2 | ||
Cable CSA 23AWG | ||
Voltage 230V | ||
Conductor Material Copper | ||
Number of Cores 2 | ||
Outside Diameter 6mm | ||
- COO (Country of Origin):
- GB
HellermannTyton Connectivity CA076 Series Cat6 Cable, 305m Cable Length, Violet Jacket - CA076 DCA
This Cat6 cable provides a high-performance cabling solution for indoor structured networks, delivering Ethernet connectivity with a violet polyethylene outer sheath. It is intended for installations requiring standard-compliant twisted-pair copper conductors and a low-smoke, halogen-free jacket suitable for occupied environments. The cable supports professional data networks where adherence to recognised wiring standards is necessary.
Features and Benefits:
• 23 AWG copper conductors for consistent signal transmission
• Twisted-pair construction reduces crosstalk in installations
• Low-smoke, halogen-free (LSOH) jacket improves safety in confined spaces
• Unshielded design simplifies termination for standard connectors
• Rated for 230V operation to match building power environments
• Withstands operating temperatures from -20 °C to 60 °C for versatility
• Twisted-pair construction reduces crosstalk in installations
• Low-smoke, halogen-free (LSOH) jacket improves safety in confined spaces
• Unshielded design simplifies termination for standard connectors
• Rated for 230V operation to match building power environments
• Withstands operating temperatures from -20 °C to 60 °C for versatility
Applications
• Suitable for structured cabling in commercial buildings
• Ideal for high-density office Ethernet deployments
• Used with patch panels and keystone jacks in racks
• Can be used for LAN backbones and horizontal runs
• Appropriate for installations requiring UKCA conformity
• Ideal for high-density office Ethernet deployments
• Used with patch panels and keystone jacks in racks
• Can be used for LAN backbones and horizontal runs
• Appropriate for installations requiring UKCA conformity
Which standards does this cable comply with?
It meets IEC 61156-5 and ISO 11801:2002 along with ANSI/TIA/EIA-568-C.2 and applicable EN standards for balanced copper cabling.
What is the recommended environment for routing and installation?
The polyethylene jacket and LSOH fire performance make it suitable for indoor routes, risers and areas where reduced smoke emission is required.
How long is the supply length and what is the typical conductor arrangement?
The cable is supplied on a 305m reel and uses four pairs in a twisted-pair configuration with 23 AWG conductors.
Are there specific dimensional attributes to consider for conduit planning?
The cable has an outside diameter of 6mm, which should be used to calculate fill for conduits and trunking.
관련된 링크들
- HellermannTyton Connectivity CA Cat6 Cat6 Cable, 305 m, Purple, Unshielded Unscreened Low Smoke Fire Retardant Zero
- Belden 1583ENH, 305 m Cat5e Ethernet Cable, Purple Polyethylene Sheath Unscreened, Unshielded
- Brand-Rex GigaPlus, 305 m Cat5e Ethernet Cable, Purple Polyethylene Sheath Unscreened, Unshielded
- Belden 7934A, 305 m Cat5e Ethernet Cable, Black Linear Low Density Polyethylene Sheath Unscreened, Unshielded
- Molex Premise Networks Cat6 Ethernet Cable, 305 m, Violet, U/UTP
- Belden, 305 m Cat6 Cat6 Cable, Black Straight to Unterminated Polyethylene Sheath, U/UTP
- Belden Unterminated, 305 m Cat5E Cable, Black Polyethylene Sheath
- HellermannTyton Connectivity CA, 305 m Cat6a Cat6A Cable, Purple, Shielded Screened Low Smoke Fire Retardant Zero
