Sensirion SGP41-D-R4, NOx, VOC Air Quality Sensor for NOx, VOC Monitoring

대량 구매 할인 기용 가능

Subtotal (1 reel of 2500 units)*

₩24,910,000.00

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 6월 05일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
릴당*
2500 - 2500₩9,964.00₩24,910,940.00
5000 - 22500₩9,764.72₩24,412,740.00
25000 +₩9,471.44₩23,680,480.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
234-8990
제조사 부품 번호:
SGP41-D-R4
제조업체:
Sensirion
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Sensirion

Gases Detected

NOx, VOC

Response Time

10 s, 250 s

Application

NOx, VOC Monitoring

Sensor Type

Air Quality Sensors

Dimensions

2.44 x 2.44 x 0.85mm

Weight

0g

Maximum Operating Temperature

50 °C

Minimum Operating Temperature

-10 °C

COO (Country of Origin):
CH
The Sensirion SGP41 is a digital MOx based gas sensor for measuring VOX and NOx. Sensirion’s CMOSens® technology offers a complete sensor system on a single chip featuring a digital I2C interface and temperature-controlled micro hotplates. Providing you with a VOC (volatile organic compound) and a NOx (nitrogen oxides) based indoor air quality signal.

The sensing element and gas Index algorithm feature robustness against contaminating gases that are present in real-world applications, supporting long-term stability as well as low drift. The Sensirion SGP41 comes in a small DFN package, great for applications where space is limited. The air quality sensor has low power consumption. Applications include air purifiers, air quality monitoring and demand-controlled ventilation systems.

Evaluation kit SEK-SVM4x for SGP40/41 is also available, see RS 234-8989 the kit contains an SVM development board equipped with the 1 x SGP41, 1 x SHT40. 1 x UART to USB adapter cable, jumper wire cable set.

Recommended operating conditions 0 to 90 %RH, -10 to +50 °C
Supply voltage 1.7 to 3.6 V
DFN 6-pin package 2.44 x 2.44 x 0.85 mm3
Device to device variation VOC ±15 VOC Index points or % (the larger)
Device to device variation NOx ±50 NOx Index points or % (the larger)

Notes


For VOC and NOx Index outputs customers need to integrate the Gas Index Algorithm (available on github) on their microcontroller.

For these non-cancellable (NC), and non-returnable (NR) products, Terms and Conditions apply.