ABB GJL131 Contactor, 12V Coil, 3-Pole, 20 A, 5.5 kW 12V, 3 NO/1 NC, 690V
- RS 제품 번호:
- 253-4843
- 제조사 부품 번호:
- GJL1313901R0017
- 제조업체:
- ABB
Subtotal (1 unit)*
₩408,140.00
제조사가 재고 비축중
- 2026년 9월 21일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩408,140.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 253-4843
- 제조사 부품 번호:
- GJL1313901R0017
- 제조업체:
- ABB
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 12V | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 20A | |
| Series | GJL131 | |
| Power Rating | 5.5kW | |
| Mount Type | DIN Rail, Wall | |
| Function | Reversing Contactor | |
| Normal State Configuration | 3 NO/1 NC | |
| Number of Auxiliary Contacts | 1 | |
| Auxiliary Contact Configuration | 0 NO/1 NC | |
| Terminal Type | Screw | |
| Control Circuit Voltage Uc | 12V | |
| Minimum Operating Temperature | -20°C | |
| Contactor Application | Control Unit | |
| Operational Current Ie | 20A | |
| Maximum Operating Temperature | 55°C | |
| Length | 46.7mm | |
| Width | 96.2mm | |
| Depth | 46.7mm | |
| Standards/Approvals | UL 60947-1, UL 60947-4-1, IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1 | |
| Pole and Throw Configuration | 3P | |
| 모두 선택 | ||
|---|---|---|
브랜드 ABB | ||
Product Type Contactor | ||
Coil Voltage 12V | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 20A | ||
Series GJL131 | ||
Power Rating 5.5kW | ||
Mount Type DIN Rail, Wall | ||
Function Reversing Contactor | ||
Normal State Configuration 3 NO/1 NC | ||
Number of Auxiliary Contacts 1 | ||
Auxiliary Contact Configuration 0 NO/1 NC | ||
Terminal Type Screw | ||
Control Circuit Voltage Uc 12V | ||
Minimum Operating Temperature -20°C | ||
Contactor Application Control Unit | ||
Operational Current Ie 20A | ||
Maximum Operating Temperature 55°C | ||
Length 46.7mm | ||
Width 96.2mm | ||
Depth 46.7mm | ||
Standards/Approvals UL 60947-1, UL 60947-4-1, IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1 | ||
Pole and Throw Configuration 3P | ||
- COO (Country of Origin):
- DE
ABB GJL131 Series Contactor, 20A Operational Current, 12V Coil Voltage - GJL1313901R0017
This contactor is a three-pole electromechanical switching device designed for motor reversing and general control in commercial, industrial and residential installations. It operates on a 12V control input and is intended for integration into control panels where Compact size and straightforward mounting are required.
Features and Benefits:
• 3P switching provides three-phase load control and simplified wiring
• 20A rated current supports moderate motor and load switching
• 690V voltage capability allows high-voltage AC applications
• 5.5kW power handling enables small to medium motor control
• 3NO1NC auxiliary contact offers supplementary control signalling
• Screw Terminal connections provide secure, tool-friendly terminations
• 20A rated current supports moderate motor and load switching
• 690V voltage capability allows high-voltage AC applications
• 5.5kW power handling enables small to medium motor control
• 3NO1NC auxiliary contact offers supplementary control signalling
• Screw Terminal connections provide secure, tool-friendly terminations
Applications
• Suitable for motor reversing and direction control in machines
• Ideal for switching three-phase loads in commercial buildings
• Used with control relays in automated production lines
• Can be used for residential three-phase distribution control
• Used for replacing a spare part in repair and maintenance tasks
• Ideal for switching three-phase loads in commercial buildings
• Used with control relays in automated production lines
• Can be used for residential three-phase distribution control
• Used for replacing a spare part in repair and maintenance tasks
What mounting options are available for panel installation?
It can be fitted to a DIN rail or secured directly to a wall-mounted panel, allowing flexible panel layouts and retrofit replacements.
What environmental temperature range can it tolerate during operation?
The device is rated to operate between -20°C and 55°C, making it suitable for typical indoor electrical distribution environments.
How many auxiliary contacts are provided and how are they configured?
There is one auxiliary contact supplied, arranged as a normally open and normally closed combination for control circuit feedback.
What Terminal type is used for line and control connections?
All connections use screw terminals to ensure reliable clamping of conductors in industrial wiring conditions.
관련된 링크들
- RS PRO Steel Perforated DIN Rail, Top Hat Compatible, 500mm x 35mm x 7.5mm
- 6EP3334-8SB00-0AY0 | Siemens SITOP PSU8200 Switched Mode DIN Rail Power Supply, 120 → 230V ac ac Input, 24V dc dc Output, 10A Output,
- H3CR-A8 AC24-48/DC12-48 | Omron H3CR Series DIN Rail, Panel Mount Timer Relay, 12 → 48 V dc, 24 → 48V ac, 2-Contact, 0.05 s
- 52104571 | Lapp Cable Gland Adaptor, M20 Exterior Thread, M16 Interior Thread, Nickel Plated Brass, SKINDICHT Series
- 515015-601 | Latching Push Button Switch, IP67, Panel Mount
- Fluke LVD2 Non Contact Voltage Detector
- BD-02PMMS-LC7001 | Amphenol Industrial Circular Connector, 2 Contacts, Panel Mount, Plug, Male, IP67, Ceres Series
- RS PRO Type K Thermocouple 2m Length, 0.3mm Diameter → +600°C