ABB GJL121 Contactor, 220V, 240 V Coil, 3-Pole, 20 A, 4 kW 220V, 240 V, 3 NO/1 NC, 690V
- RS 제품 번호:
- 253-4785
- 제조사 부품 번호:
- GJL1213901R0015
- 제조업체:
- ABB
Subtotal (1 pack of 5 units)*
₩1,797,140.00
제조사가 재고 비축중
- 2026년 11월 06일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 | 한팩당* |
|---|---|---|
| 5 + | ₩359,428.00 | ₩1,797,140.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 253-4785
- 제조사 부품 번호:
- GJL1213901R0015
- 제조업체:
- ABB
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 220V, 240V | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 20A | |
| Series | GJL121 | |
| Power Rating | 4kW | |
| Mount Type | DIN Rail, Wall | |
| Function | Control Unit | |
| Normal State Configuration | 3 NO/1 NC | |
| Number of Auxiliary Contacts | 1 | |
| Auxiliary Contact Configuration | 0 NO/1 NC | |
| Terminal Type | Screw | |
| Contactor Application | Commercial | |
| Control Circuit Voltage Uc | 220V, 240V | |
| Operational Current Ie | 20A | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 55°C | |
| Standards/Approvals | UL 60947-1, UL 60947-4-1, IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1 | |
| Length | 46.7mm | |
| Depth | 46.7mm | |
| Width | 96.2mm | |
| Pole and Throw Configuration | 3P | |
| 모두 선택 | ||
|---|---|---|
브랜드 ABB | ||
Product Type Contactor | ||
Coil Voltage 220V, 240V | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 20A | ||
Series GJL121 | ||
Power Rating 4kW | ||
Mount Type DIN Rail, Wall | ||
Function Control Unit | ||
Normal State Configuration 3 NO/1 NC | ||
Number of Auxiliary Contacts 1 | ||
Auxiliary Contact Configuration 0 NO/1 NC | ||
Terminal Type Screw | ||
Contactor Application Commercial | ||
Control Circuit Voltage Uc 220V, 240V | ||
Operational Current Ie 20A | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 55°C | ||
Standards/Approvals UL 60947-1, UL 60947-4-1, IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1 | ||
Length 46.7mm | ||
Depth 46.7mm | ||
Width 96.2mm | ||
Pole and Throw Configuration 3P | ||
- COO (Country of Origin):
- DE
ABB GJL121 Series Contactor, 20A Operational Current, 220V Coil Voltage - GJL1213901R0015
This contactor is a three-pole switching device designed to control and reverse three-phase motors and loads in commercial electrical installations. It operates within low-voltage control systems and is intended for panel or DIN-rail mounting where reliable switching of motors up to typical small-power ratings is required.
Features and Benefits:
• 20A switching current supports moderate motor loads
• 690V rated contact voltage allows high-voltage switching capability
• 220/240V control circuit Uc accommodates common Coil supplies
• Reversing contact arrangement enables motor direction control
• 3NO1NC auxiliary layout provides one normally closed signalling contact
• Screw terminals permit secure conductor connections
• 690V rated contact voltage allows high-voltage switching capability
• 220/240V control circuit Uc accommodates common Coil supplies
• Reversing contact arrangement enables motor direction control
• 3NO1NC auxiliary layout provides one normally closed signalling contact
• Screw terminals permit secure conductor connections
Applications
• Suitable for motor direction control in HVAC systems
• Ideal for commercial conveyor drive switching
• Used with automated control panels for building services
• Can be used for reversing pumps in water treatment plants
• Ideal for commercial conveyor drive switching
• Used with automated control panels for building services
• Can be used for reversing pumps in water treatment plants
What mounting options are available for installation?
It can be mounted on a DIN rail or affixed to a wall, allowing flexible panel layouts and retrofit installations.
What temperature range should be maintained for reliable operation?
The device is designed to operate between -20°C and +55°C to suit typical indoor industrial environments.
How many poles and auxiliary contacts does it provide?
It provides three main poles for load switching and a single auxiliary contact configured as normally closed for control feedback.
Which Terminal style is used for electrical connections?
Screw-type terminals are specified to ensure secure and vibration-resistant conductor retention.
관련된 링크들
- 6EP3334-8SB00-0AY0 | Siemens SITOP PSU8200 Switched Mode DIN Rail Power Supply, 120 → 230V ac ac Input, 24V dc dc Output, 10A Output,
- RS PRO Steel Perforated DIN Rail, Top Hat Compatible, 500mm x 35mm x 7.5mm
- H3CR-A8 AC24-48/DC12-48 | Omron H3CR Series DIN Rail, Panel Mount Timer Relay, 12 → 48 V dc, 24 → 48V ac, 2-Contact, 0.05 s
- 515015-601 | Latching Push Button Switch, IP67, Panel Mount
- BD-02PMMS-LC7001 | Amphenol Industrial Circular Connector, 2 Contacts, Panel Mount, Plug, Male, IP67, Ceres Series
- 52104571 | Lapp Cable Gland Adaptor, M20 Exterior Thread, M16 Interior Thread, Nickel Plated Brass, SKINDICHT Series
- RS PRO Type K Thermocouple 2m Length, 0.3mm Diameter → +600°C
- Fluke LVD2 Non Contact Voltage Detector