ABB GJL121 Contactor, 110V, 125 V Coil, 4-Pole, 20 A, 2.2 kW 110V, 125 V, 2 NO/2 NC, 690V
- RS 제품 번호:
- 253-4779
- 제조사 부품 번호:
- GJL1213501R0004
- 제조업체:
- ABB
Subtotal (1 unit)*
₩140,160.00
일시적 품절
- 9999년 12월 31일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩140,160.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 253-4779
- 제조사 부품 번호:
- GJL1213501R0004
- 제조업체:
- ABB
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 110, 125V | |
| Number of Poles | 4 | |
| Contact Voltage | 690V | |
| Contact Current | 20A | |
| Power Rating | 2.2kW | |
| Series | GJL121 | |
| Mount Type | DIN Rail, Wall | |
| Function | Mini Contactor | |
| Normal State Configuration | 2 NO/2 NC | |
| Number of Auxiliary Contacts | 0 | |
| Auxiliary Contact Configuration | 0 NO/0 NC | |
| Terminal Type | Screw | |
| Control Circuit Voltage Uc | 110, 125V | |
| Contactor Application | Control Unit | |
| Operational Current Ie | 20A | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 55°C | |
| Width | 52.5mm | |
| Depth | 46.7mm | |
| Standards/Approvals | IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | |
| Length | 46.7mm | |
| Pole and Throw Configuration | 4P | |
| 모두 선택 | ||
|---|---|---|
브랜드 ABB | ||
Product Type Contactor | ||
Coil Voltage 110, 125V | ||
Number of Poles 4 | ||
Contact Voltage 690V | ||
Contact Current 20A | ||
Power Rating 2.2kW | ||
Series GJL121 | ||
Mount Type DIN Rail, Wall | ||
Function Mini Contactor | ||
Normal State Configuration 2 NO/2 NC | ||
Number of Auxiliary Contacts 0 | ||
Auxiliary Contact Configuration 0 NO/0 NC | ||
Terminal Type Screw | ||
Control Circuit Voltage Uc 110, 125V | ||
Contactor Application Control Unit | ||
Operational Current Ie 20A | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 55°C | ||
Width 52.5mm | ||
Depth 46.7mm | ||
Standards/Approvals IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | ||
Length 46.7mm | ||
Pole and Throw Configuration 4P | ||
- COO (Country of Origin):
- DE
ABB GJL121 Series Contactor, 20A Contact Current, 110 to 125V Control Circuit Voltage - GJL1213501R0004
This contactor is a Compact switching device designed for control circuits in commercial, industrial and residential installations. It operates with a control circuit voltage in the 110–125V range and switches alternating loads up to 20 A at voltages as high as 690 V, providing a Compact solution for motor and load control where space is limited.
Features and Benefits:
• Four poles allowing switching of multi‑phase loads and improved isolation
• Screw terminals for secure, high‑integrity electrical connections
• Rated operational current 20 A enabling moderate power switching
• Power handling of 2.2 kW suitable for small motor drives and equipment
• Conforms to IEC and UL contactor standards for consistent performance
• DIN rail or wall mounting gives flexible installation options
• Screw terminals for secure, high‑integrity electrical connections
• Rated operational current 20 A enabling moderate power switching
• Power handling of 2.2 kW suitable for small motor drives and equipment
• Conforms to IEC and UL contactor standards for consistent performance
• DIN rail or wall mounting gives flexible installation options
Applications
• Suitable for control panels in light industrial automation systems
• Ideal for switching small three‑phase motors in workshops
• Used with HVAC equipment in commercial buildings
• Can be used for residential distribution and load control setups
• Ideal for switching small three‑phase motors in workshops
• Used with HVAC equipment in commercial buildings
• Can be used for residential distribution and load control setups
What mounting methods are available for installation?
It supports both DIN‑rail and direct wall mounting to suit panel and enclosure arrangements.
How many poles does it provide and why does that matter?
It is a four‑pole device, which permits simultaneous switching of all conductors in multi‑phase circuits for coordinated control.
Which Terminal style is used and what is the benefit?
Screw‑type terminals are provided to ensure a robust mechanical and electrical connection for conductors.
What operating temperature range should be observed?
The device is designed to function between −20 °C and 55 °C, accommodating typical indoor industrial environments.
관련된 링크들
- RS PRO Steel Perforated DIN Rail, Top Hat Compatible, 500mm x 35mm x 7.5mm
- 6EP3334-8SB00-0AY0 | Siemens SITOP PSU8200 Switched Mode DIN Rail Power Supply, 120 → 230V ac ac Input, 24V dc dc Output, 10A Output,
- H3CR-A8 AC24-48/DC12-48 | Omron H3CR Series DIN Rail, Panel Mount Timer Relay, 12 → 48 V dc, 24 → 48V ac, 2-Contact, 0.05 s
- 52104571 | Lapp Cable Gland Adaptor, M20 Exterior Thread, M16 Interior Thread, Nickel Plated Brass, SKINDICHT Series
- 515015-601 | Latching Push Button Switch, IP67, Panel Mount
- Fluke LVD2 Non Contact Voltage Detector
- BD-02PMMS-LC7001 | Amphenol Industrial Circular Connector, 2 Contacts, Panel Mount, Plug, Male, IP67, Ceres Series
- RS PRO Type K Thermocouple 2m Length, 0.3mm Diameter → +600°C